6. Data In/Out
6.7 Data Protection
I
-253
2) Protection of user parameters and common variables (KEY 2)
When KEY 2 is turned OFF, the operation items listed in Table 2 are inhibited.
Table 2 Data protection by KEY 2
No.
Operation
Screen
1
Machining parameter setting
PARAM/PROCESS
2
Control parameter ON/OFF
PARAM/CONTROL
3
Axis parameter setting
PARAM/AXIS
4
Barrier data
PARAM/BARRIER
5
Common variable setting
MONITOR/COMMON VARIABLE
6
I/O basic parameter setting
IN/OUT (PARAMETER)
7
Parameter tape input
IN/OUT/INPUT
8
Parameter tape output
IN/OUT/OUTPUT
(Note)
When KEY 2 is OFF, pressing any key other than the MENU key on the screens
corresponding to numbers 1 to 6 in Table 2 does not enter any data, but displays
message "DATA PROTECT".
When an attempt is made to perform the operation of number 7 or 8, pressing the
INPUT
key
cannot input or output any data, causing message "DATA PROTECT" to be displayed.
3) Protection of machining program (KEY 3)
When KEY 3 is turned OFF, the operation items listed in Table 3 are inhibited.
Table 3 Data protection by KEY 3
No.
Operation
Screen
Extended
operation menu
1
Storing MDI data in memory
MDI
MDI ENTRY
2
Editing machining program
EDIT
—
3
Creating machining program
EDIT
PROGRAM
4
Setting comments of stored program
EDIT
FILE
5
Storing and checking machining program in
memory
IN/OUT/INPUT
—
6
Erasing machining program (single, group, all)
IN/OUT/ERASE
—
7
Setting comment of stored program
IN/OUT/FILE
—
8
Copying, condensing, and merging a machining
program, and changing its number
IN/OUT/COPY
—
9
Outputting machining program
IN/OUT/OUTPUT
—
10 Correcting buffer of machining program
MONITOR/
COORDINATE
—
(Note1)
When KEY 3 is OFF, pressing any key other than the MENU key on the screens
corresponding to numbers 1 to 4 and 6 to 8 in the above table or the extended operation
menu screen causes message "DATA PROTECT" to be displayed; no data can be input.
When an attempt is made to perform the operation of number 5, 9, or 10 in Table 3,
pressing the
INPUT
key (for 5 and 9) or the cursor key (for 10) causes message "DATA
PROTECT" to be displayed without the operation coming into effect.
(Note2)
Buffer correction is possible for the program stored in the IC card or tape even if KEY3 is
OFF.