3. Tool Offset (M system)
3.3 Tool Life
I
-128
Refer to "3 (I). Tool Offset (L system)" for L system.
Set 11 in # ( ), then press the
INPUT
key.
To register data exceeding the
number of data pieces that can
be displayed on a screen, set the
# number only. New data can be
registered.
OFFSET
REGIST
LIFE
MENU
7 12345678
4 220 -345.678
100.000 12345 1234 234(min)
8 1234567
3 120 112.340
30.000 11111 123 45(min)
9
123456
2 111 122.220
20.000 44444 100 50(set)
10
12345
1 002 11.234
100.123 100 50 15(cyc)
# ( 11) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )
[TOOL LIFE]
TOOL
4.2/2
GROUP 123
# TOOL NO. ST FROM
L-CMP
R-CMP
AUX
LIFE
USED
11
12
13
14
(3)
Data
change
1) Display the TOOL LIFE data screen for the group in which the tool whose data is to be
changed is registered.
2) Set the # number of the data to be changed and new data in given parenthesis pairs of the
setting area, then press the
INPUT
key.
3) After setting, the # number is incremented by one and is set in setting area ( ).
4) To change data under # number not displayed on the screen, change the screen by using the
NEXT
PAGE
or
PREVIOUS
PAGE
key or setting the number in setting area # ( ).
5) By changing a registered tool number to 0, the tool can be deleted.
(4) Deletion in group units
To delete all data in one group, select the TOOL LIFE data screen for the group to be deleted and
press the
SHIFT
key,
C.B
CAN
key, then
INPUT
key.
(Note)
If any other key has been pressed before the
INPUT
key is pressed, the TOOL LIFE data will
not be deleted.
3.3.4 Clear of All TOOL LIFE Data (HEAD, NEXT, GROUP LIST Screen Page 1)
To clear all data, select the HEAD, NEXT, GROUP LIST screen and press
SHIFT
key,
C.B
CAN
key, then
INPUT
key.
(Note)
If any other key has been pressed before the
INPUT
key is pressed, the TOOL LIFE data will
not be cleared.