4. Absolute Position Detection System
4.3 Starting up Absolute Position Detection System
III
-17
(3)
Zero-point
initialization
The jog or handle is used with the "ABS. POSITION SET" screen to perform zero-point initialization.
The progress of the initialization operation is displayed in the STATE field of the same screen.
The operation procedure will differ
depending on the zero point
initialization method. Each procedure is
explained below.
(a) Machine end stopper method
(#2049 type: 1)
The machine end stopper method
includes two initialization modes:
manual and automatic.
(i) Manual
initialization
With this method, the axis is
pressed against the machine end
stopper using handle or JOG.
Before performing zero-point
initialization, specify the following
parameter (for details, see Alarm/
Parameter Manual):
ABS-SRV
ADJUST
HISTORY CMPOSIT MENU
[ABS. POSITION SET]
ALARM/DIAGN 5.2/2
<X>
<Y>
<Z>
TYPE
NO-STOPPER STOPPER NO-STOPPER
STATE
NG
NG
NG
TO END
-12345.678
0.000
1.234
MACHINE
-12345.678 NOT PASS 0.000
#
0 INIT SET
0
1
1
1 ORIGIN
0
0
1
2 ZERO
-12345.678
0.000
1.234
#( )
( )
( )
( )
#2054 clpush (Current limit)