5. Stored Stroke Limit
5.2 Stored stroke limit II
III
-29
5.2 Stored stroke limit II
The boundary is set with the parameters (axis parameters #8204 OT-CHECK-N, #8205 OT-CHECK-P)
or with the program commands. The inside or outside of the set boundary is the prohibited range.
Whether the inside or outside of the range is prohibited is determined by the parameter (#8210
OT-INSIDE). When the inside is selected, this function is called stored stroke limit IIB.
When using program commands, entry of the tool into the prohibited range is prohibited with G22, and
entry into the prohibited range is enabled with G23.
The stored stroke limit II function can be invalidated for each axis with the parameter setting (#8202
OT-CHECK OFF: 1).
(Note)
G22/G23 is valid for the G code system 6/7.
X Z
Movement
prohibited
range
Moveable range
Outsid
e
Outsid
e
Moveable range
Outsid
e
Inside
Moveable range
Inside
Inside
Moveable range
Содержание EZMotion-NC E60 Series
Страница 1: ......
Страница 15: ...I OPERATION SECTION ...
Страница 361: ...II MACHINE OPERATION MANUAL ...
Страница 399: ...III SETUP ...
Страница 472: ...IV APPENDIXES ...
Страница 510: ......