8. Maintenance Functions
8.2 Data Sampling
III
-64
8.2 Data Sampling
The NC internal data (speed output from NC to drive unit, or feedback data from drive unit, etc.) can
be sampled and output serially.
(Setup parameter "#1224 aux08/bit0" must be set to "1" to use this function.)
(Note 1)
This function is not available with E60 system software version A.
8.2.1 Specifications
•
Sampling cycle
: 1.7ms * 2 * scale
•
Number of sampled axes
: E60:1 to 5 axes (Servo axes*4
+
spindle*1)
E68:1 to 8 axes (Servo axes*6
+
spindle*2)
•
Number of sampled points
: 1 to 8 points
•
Number of sampled data items : Max. 3,072 (long-type data conversion)
(Note 2)
The maximum number of sampled data items is the number of all sampled points. When
the data to be sampled increases, the number of sampled points will drop per data item.
[Restrictions]
(1) Do not use this function together with the input/output function(PLC) or the onboard function.
(2) The data set with this function is not output to the parameters.
(3) When the power is turned ON, "#0 Sampling start" will be set to "0" (sampling stop).