Appendix 6. Operation Messages on Setting and Display Unit
IV
-21
Error No.
Error message
Details
E07 RESET
END
∆
• The input/output operations were forcibly stopped by reset‚ etc.
(including EMG).
E08 PHYSICAL
ERR
×
• The input/output parameter setting or input/output unit side
setting was incorrect.
E09 TIME
OUT
×
• The input/output unit parameter "#9116 TIME-OUT SET" setting
was too short.
• There is no EOB code in the machining program.
E10 MEMORY
OVER
×
• The program cannot be written because the memory capacity is
exceeded.
• This error occurs when the MDI data setting on the MDI screen
exceeds 500 characters‚ or when saving MDl‚ editing or making a
program on the edit screen‚ input on the data input/output screen‚
program copy‚ etc.
E11
PROG. No. DUPLI
∆
• When registering a machining program in the memory‚ a program
with the same No. as the designated program No. was found in
the memory. Refer to the program file to find a program No. not
being used‚ and reset the program No.
• A program with the same No. as the machining program to be
copied from the memory was found in the IC card.
• This error occurs during MDI registration in the MDI screen or
during creation of a program in the edit screen.
E12 FILE
ENTRY
OVER
×
• When registering a machining program in the memory‚ the No. of
programs determined in the specifications is exceeded‚
preventing registration.
This error occurs during MDI registration in the MDI screen‚
creation of a program in the edit screen‚ data input in the data
input/output screen‚ and program copy.
E13 NB
NOT
FOUND
∆
• The block with the designated sequence No. or block No. does
not exist in the designated program.
E14 PROG.
NOT
FOUND
∆
• The designated program is not found in the memory.
• A machining program in the IC card was searched during
emergency stop.
• The corresponding program No. was not found with operation
search in the tape or memory operation mode during graphic
check.
E15 EDIT
LOCK
B
×
• An operation (edit‚ input/output‚ buffer correction‚ etc.) inhibited
for machining program B was attempted.
E16 EDIT
LOCK
C
×
• An operation (edit‚ input/output‚ buffer correction‚ etc.) inhibited
for machining program C was attempted.
E17
PARITY H ERR
×
• A parity H error was detected during data input‚ etc.
• Check the paper tape or input device. This error may occur if the
paper tape is dirtied with oil‚ etc.