4. Absolute Position Detection System
4.3 Starting up Absolute Position Detection System
III
-23
(Note
1)
If the basic point is set when the grid has not been passed once after turning the power ON,
the message "NOT PASS" will display. Return to a point before the last grid, and then
repeat from step 6.
(Note
2)
If the first grid point is covered by the grid mask ("#2028 grmask" on [zero-return parameter]
screen) as a result of marked point return at step 9, the axis stops at the next grid point.
Note that zero-point shift ("#2027 G28sft" on [ZERO-RTN PARAM] screen) is invalid.
(Note
3)
Reconfirm the absdir direction if the machine does not move in step 8. The machine will
move only in the positive direction when set to 0, and the negative direction when set to 1.
(c) Common precautions for dogless type absolute position detection
(i) Examples of setting "#2 ZERO" parameter
The coordinate value of the absolute basic point (mechanical basic position or electrical basic
position) looking from the basic machine coordinate zero point is set for "#2 ZERO" parameter.
(Example 1)
The zero point is
determined at the
position 50.0 to the
front of the absolute
position basic
position on the
positive side.
Zero point of basic machine
coordinate
"ZERO"=50.0
Absolute position
basic point
(Machine basic position
or electrical basic
position)
(Example 2)
The zero point is
determined at the
position 400.0mm to
the front from the
machine basic
position or absolute
position basic point at
the negative side.
Zero point of basic
machine coordinate
"ZERO"=-400.0
Absolute position
basic point
(Machine basic position
or electrical basic
position)
(Example
3)
If it is desired to create the zero point of the basic machine coordinate on a grid point, the value
indicated in "TO END" is used to calculate the value to be set to the "#2 ZERO" parameter as
shown in the example below. The value indicated in "TO END" is the distance from the
machine basic position to the grid point right before the end. (If the coordinates of the absolute
position basic point are used for "#2 ZERO", TO END does not need to be considered.)
The zero point is
determined at the
third grid point
(10.0mm grid-point
intervals) when "TO
END" indicates
−
5.3
at the basic position
at the positive side.
(Example for 10.0mm
grid interval.)
Zero point of basic machine
coordinate system
"ZERO"=25.3
Machine basic
position
"TO END" = –5.3
10.0
10.0
Содержание EZMotion-NC E60 Series
Страница 1: ......
Страница 15: ...I OPERATION SECTION ...
Страница 361: ...II MACHINE OPERATION MANUAL ...
Страница 399: ...III SETUP ...
Страница 472: ...IV APPENDIXES ...
Страница 510: ......