background image

calrec.com

Radio Production System

TYPE R 

INSTALLATION MANUAL

Содержание TYPE R

Страница 1: ...calrec com Radio Production System TYPE R INSTALLATION MANUAL...

Страница 2: ...ational usage Calrec Audio Ltd reserve the right to change specifications without notice E O E The established policy of Calrec Audio Ltd is to seek improvements to the design specifications and manuf...

Страница 3: ...sk Stand 720 999002 44 Fader LSP on Desk Stand 720 999003 46 LSP In Desk Mounting 720 999004 47 SSP In Desk Mounting 720 999005 49 Fader Panel In Desk Mounting 720 999006 51 Fader Panel Linking 720 99...

Страница 4: ...gement Settings 90 AoIP Network Examples 101 Designing an AoIP AES67 Network 102 Type R AoIP AES67 network examples 102 Recommended third party equipment 102 Redundancy 104 Switch Port Quantities 104...

Страница 5: ...calrec com TYPE R INFORMATION...

Страница 6: ...fic to this document please contact enquiries calrec com Whenever you contact Calrec Customer Support please have the following information to hand Name Company Email Address Full details of enquiry e...

Страница 7: ...wrapping Calrec Audio Limited can supply anti static wrapping upon request This applies particularly to digital products due to the types of devices and very small geometries used in their fabrication...

Страница 8: ...t we recommend using a soft anti static cloth lightly dampened with water if required Explanation of Warning Symbols Triangular warning symbols contain a black symbol on a yellow background surrounded...

Страница 9: ...DSP are all self contained within the 2U Core unit which has two IEC connectors to provide PSU redundancy The core operates at 44 1 48 96 kHz and supports up to 3 Consoles A number of DSP packages ar...

Страница 10: ...10 TYPE R Radio Production System...

Страница 11: ...calrec com TYPE R START UP GUIDE...

Страница 12: ...t are present with the correct serial numbers A print out of the packing list will have been provided alongside the shipping documentation The packing list is a document named with your sales order nu...

Страница 13: ...lit and after approximately 30 seconds the OK LED will light solid green to indicate a good status The Recover Led should be lit Green or not lit Fan Fail PSU Fail LEDs should not be lit 4 Configure...

Страница 14: ...neral Configuration page will be displayed 3 Set the system date time 4 You may also set new System and Core names here These names will be used by the system to identify and announce cores as well as...

Страница 15: ...customer contact s CALREC ONLINE SHOP SOFTWARE UPGRADE LICENCE PAGE CORE CONFIGURE DSP LICENCES PAGE 1 To install a licence key open the Core Configure application and navigate to System DSP Licences...

Страница 16: ...n the Add ancillary panel dialogue See below right Note Where there are multiple fader panels multiple Add ancillary panel buttons will be available This is to allow you to position the panel in the s...

Страница 17: ...esources before you continue Cisco Switch Management Settings for Physical Surface Panels The Cisco SG350 switch used for Surface Panel Interfacing needs to have its Energy Detect Mode Short Reach and...

Страница 18: ...in the 192 168 30 24 for Primary AoIP port and 192 168 31 24 Secondary AoIP port address ranges and can be adapted as required Artel Switch Management Settings for AoIP AES67 Networks The Artel ARG s...

Страница 19: ...settings should boot into config mode automatically To enter config mode manually follow the instructions below Fader panels hold down the first 3 buttons on the bottom button row before powering dur...

Страница 20: ...the core 2 If the Core has been configured with a surface layout that matches the connected panels the panels will be discovered by the core If the panels are running a different software version to t...

Страница 21: ...le Chrome type 172 16 255 25 into the address bar and press enter to navigate to the Assist landing page 2 In the menu on the left hand side navigate to Shows snapshots then Shows in the sub menu 3 In...

Страница 22: ...22 TYPE R Radio Production System Start Up Guide SURFACE PANEL CONFIGURATION WITH ASSIST PC CONNECT OPTIONS TO SETUP MANAGEMENT STUDIO A...

Страница 23: ...panel 4 Repeat this process for each Soft Panel in your surface Please refer to the Type R Assist and Console Panel Operation manual for more information on Type R Soft Panel Layouts 11 CREATE LAYOUTS...

Страница 24: ...al Audio interface boxes types available for the Type R which are show in outline below The AD6501 is a 4 AES In with SRC 4 AES Out 8 Mic Line In with 48v 8 Line out Combo I O box with 2 x 6 35mm 1 4...

Страница 25: ...t Important Currently the IP addresses and subnet masks assigned to the core s Connect server are fixed It will be possible to edit these settings from software release v1 2 Until then all AoIP device...

Страница 26: ...onnect the next IO device and repeat steps 3 4 5 Once all IO box core AoIP device network interfaces are known to be set with unique IP addresses they may all be connected to the same network All IO b...

Страница 27: ...be tested for use as a single studio system CALREC CONNECT SHOWING THE TYPE R CORE AOIP PORTS READY FOR CREATING TRANSMIT AND RECEIVE STREAMS CALREC CONNECT SHOWING THE COMBO AOIP DEVICE PORTS READY...

Страница 28: ...our surface panels and to record the serial number fader range and label details of each panel for later reference After configuring the surface panels you may want to attach labels to them A blank la...

Страница 29: ...01 24 16 15th 25 00011001 172 17 101 25 16 16th 26 00011010 172 17 101 26 16 17th 27 00011011 172 17 101 27 16 18th 28 00011100 172 17 101 28 16 19th 29 00011101 172 17 101 29 16 20th 30 00011110 172...

Страница 30: ...umber Primary interface IP Address Subnet mask Secondary interface IP Address Subnet mask 1 192 168 30 1 24 192 168 31 1 24 2 192 168 30 2 24 192 168 31 2 24 3 192 168 30 3 24 192 168 31 3 24 4 192 16...

Страница 31: ...splaying and controlling the fader surface saving and loading snapshots and patching inputs and outputs to the channels and buses There are then various sections about parameter access including proce...

Страница 32: ...32 TYPE R Radio Production System...

Страница 33: ...calrec com TYPE R CONTROL SURFACE DIMENSIONS...

Страница 34: ...duction System Control Surface Dimensions TOP VIEW SIDE VIEW IM6413 6 WAY FADER PANEL The following diagrams show the surface measurements of the IM6413 6 way Fader Panel in millimetres mm inches in S...

Страница 35: ...35 FRONT VIEW IM6413 6 WAY FADER PANEL REAR VIEW IM6413 6 WAY FADER PANEL Note These panels can be fastened together to form larger console surfaces...

Страница 36: ...n System Control Surface Dimensions TOP VIEW SIDE VIEW MU6411 LARGE SOFT PANEL The following diagrams show the surface measurements of the MU6411 Large Soft Panel in millimetres mm inches in FRONT VIE...

Страница 37: ...37 BOTTOM VIEW MU6411 LARGE SOFT PANEL REAR VIEW MU6411 LARGE SOFT PANEL Note These panels can be fastened together to form larger console surfaces...

Страница 38: ...System Control Surface Dimensions TOP VIEW SIDE VIEW MU6410 SMALL SOFT PANEL The following diagrams show the surface measurements of the MU6410 Small Soft Panel all in millimetres mm inches in FRONT V...

Страница 39: ...39 BOTTOM VIEW MU6410 SMALL SOFT PANEL REAR VIEW MU6410 SMALL SOFT PANEL Note These panels are designed to be located wherever a simple control interface is required...

Страница 40: ...40 TYPE R Radio Production System...

Страница 41: ...calrec com TYPE R FIXING BRACKET ASSEMBLY INSTRUCTIONS...

Страница 42: ...dge 17mm to desk surface without feet with feet 20 5mm Assembly Tools required not supplied 7mm adjustable spanner wrench open ended PZ2 screw driver bit Determine height and location required on surf...

Страница 43: ...Wood screws not supplied Saw Follow instructions for 720 999006 Fader in desk mounting kit but Fader opening size will require extending to 418mm 16 45in x 247mm 9 7in Offer up fader panel through ope...

Страница 44: ...fixing hole positions see Fig2 a bottom edge 15mm to desk surface without feet with feet 20mm b bottom edge 25mm to desk surface without feet with feet 30mm Stand Base With stick on feet supplied Wit...

Страница 45: ...SSP with bracket Item 1 from base item 2 Fix base Item 2 to desk top with screws not provided using the 2 marked fixing holes as reference Re attach interface bracket Item 1 to base Item 2 with 3 x M...

Страница 46: ...attach using 2 Screws item 6 with washers item 5 7 with plain washer towards bracket as shown in Fig 4 Loosely attach LSP bracket Item 1 to LSP with 4 screws Item 6 and washers item 5 6 Align with fi...

Страница 47: ...mm FIG 2 LARGE SOFT PANEL IN DESK MOUNTING MODES A B FIG 1 LARGE SOFT PANEL IN DESK Flush mounting options a Fig 2 for desk thickness 9 20mm b Fig 2 for desk thickness 40 50mm c Fig 3 for desk thickne...

Страница 48: ...in bracket Item 1 with LSP and attach stand using 4 x M4 screws Item 5 with washers Items 3 4 Note plain washer should be nearest bracket As shown Fig 5 Fitting to desk surface Cut hole in desk 247mm...

Страница 49: ...G 2 SMALL SOFT PANEL IN DESK MOUNTING MODES A B FIG 1 SMALL SOFT PANEL IN DESK Flush mounting options a Fig 2 for desk thickness 10 20mm b Fig 2 for desk thickness 40 50mm c Fig 3 for desk thickness 0...

Страница 50: ...washer should be nearest bracket As shown Fig 6 Set Panel ID as once fitted it may be difficult to do so and offer up the SSP through the hole in desk from the underside Fitting to desk surface Fix br...

Страница 51: ...mm to 25mm 56mm 15 25mm FIG 2 FADER PANEL IN DESK MOUNTING MODE A FIG 1 FADER PANEL IN DESK Flush mounting options a Fig 2 for desk thickness 15 25mm b Fig 3 for desk thickness 0 25mm FIG 3 FADER PANE...

Страница 52: ...ig 2 3 Align holes in bracket Item 1 with Fader Panel and attach stand using 4 x M4 screws Item 4 with washers Items 3 6 Note plain washer should be nearest bracket As shown Fig 5 Fitting to desk surf...

Страница 53: ...uire extending to 418mm 16 45in x 247mm 9 7in Offer up fader panel through opening from underside Fix brackets 720 999006 item2 to underside of desk with 4 screws not supplied suitable for desk surfac...

Страница 54: ...embly Instructions FADER PANEL LINKING 720 999007 Fader panel IM6413 to Fader Panel IM6413 Linking Option FIG 1 FADER PANEL TO FADER PANEL LINKING FIG 2 LINKING PANEL PROCEDURE 1st Panel 2nd Panel 1st...

Страница 55: ...ake 1st Fader panel from left and turn fader panel over with front edge towards you Attach 2 brackets Item 1 to left hand side of fader panel Align holes in bracket Item 1 with Fader panel and attach...

Страница 56: ...ctions LARGE SOFT PANEL LINKING 720 999008 Large Soft panel MU6411 to Large Soft Panel MU6411 Linking Option FIG 1 LARGE SOFT PANEL TO LARGE SOFT PANEL LINKING FIG 2 LINKING PANEL PROCEDURE 1st Panel...

Страница 57: ...nels located as you require take 1st Fader panel from left and turn the panels over with top of the panels towards you Align holes in bracket Item 1 with Fader panel and attach using 4 x M4 screws Ite...

Страница 58: ...58 TYPE R Radio Production System...

Страница 59: ...calrec com TYPE R SYSTEM ELEMENTS...

Страница 60: ...nectors which connect to the various surfaces via PoE switches Typically each of these connect to a separate PoE switch interfacing to a number of Fader LSP and SSP panels More than one connection is...

Страница 61: ...faders has 4 large user definable buttons a dedicated 96x96 pixel TFT display for fader status information and at the top of each fader are 2 user buttons a rotary control with integrated push switch...

Страница 62: ...or on the rear edge of the panel provides both power and data connections MU6410 Small Soft Panel SSP This panel shown bottom right consists of a smaller 1024x600 pixel touch sensitive TFT display for...

Страница 63: ...the up on position represents a binary 1 Each switch binary bit equates to a decimal value starting at 1 for the least significant bit The remaining switches are double the value of their less signif...

Страница 64: ...ne In with 48v and 16 Line out Analogue I O box with 6 GPI and 6 GPO interfaces The JD6503 is an 8 AES In with SRC and 8 AES Out AES I O Box with 6 GPI and 6 GPO interfaces In addition to the 2 x IEC...

Страница 65: ...ample below shows two switches which offers a diversity of connections to the 24 fader Console In addition to the panels a PC is connected providing the Calrec Assist application for configuration and...

Страница 66: ...TWORK CONFIGURATION AT A GLANCE The drawing below shows an overview of the factory default network configuration of each device in a Type R system Please refer to the Surface Panel Layout and AoIP Net...

Страница 67: ...67...

Страница 68: ...7 1 22 16 172 18 1 22 16 172 19 1 22 16 Configure 172 29 1 23 16 172 17 1 23 16 172 18 1 23 16 172 19 1 23 16 Router 172 29 1 24 16 Twin Controller 172 29 1 25 16 Rear Interface 1 2 1 2 1 2 1 2 5 6 Su...

Страница 69: ...failure or a loss of AC power input will generate a system status error message The two PSU s employ load sharing If one PSU fails the other will automatically take over the full load with no loss of...

Страница 70: ...70 TYPE R Radio Production System...

Страница 71: ...calrec com TYPE R SYNC AUDIO GPIO CONNECTIONS...

Страница 72: ...uire that all equipment connected to the audio console s digital inputs and outputs are locked to the same referenced sync source as the console to ensure clean audio It is of paramount importance tha...

Страница 73: ...ne inputs Note that there are 8 x 48v indicator LEDs to show when phantom power is being applied to each input to this connector The pinout for analogue inputs 9 16 on the AD6502 Analogue I O Box is i...

Страница 74: ...01 Combo I O Box and the AD6502 Analogue I O Box and conforms to the AES59 Tascam standard Analogue Audio Out RJ45 type Connector This connector is used for 2 x balanced Line outputs The pinout for an...

Страница 75: ...or appears on the UR6500 Core Box AD6501 Combo I O Box and the JD6503 AES I O Box and conforms to the AES59 Tascam standard AES Audio In RJ45 type Connector This connector is used for 1 x AES input po...

Страница 76: ...x and conforms to the AES59 Tascam standard AES Audio Out RJ45 type Connector This connector is used for 1 x AES output ports The pinout for AES output ports 2 3 4 is identical to the port 1 pinout Th...

Страница 77: ...GPO connector GPI inputs Each GPI connector carries six GPI circuits based on a simple opto isolated design capable of interfacing with any DC signal between 5V and 24V Each input is designed to be a...

Страница 78: ...6 on Pin 8 This connector appears on the UR6500 Core Box x 2 AD6501 Combo I O Box AD6502 Analogue I O Box and the JD6503 AES I O Box GPO RJ45 type Connector This connector is used for 6 x GP Outputs N...

Страница 79: ...calrec com TYPE R CORE DSP PACK OPTIONS...

Страница 80: ...nnel paths R20 Base 20 DSP channel paths 1 x Console 20 DSP channel paths 8 Aux buses 8 Group buses 3 Main buses R40 Option 40 DSP channel paths 1 1 x Console 40 DSP channel paths 16 Aux buses 8 Group...

Страница 81: ...are 4 variants depending on which DSP packages have been made available from 20 to 120 DSP channels Mix buses will also vary depending on the DSP channel size with only the two larger DSP packs R80 an...

Страница 82: ...Mix Minus Mix Paths 4 4 Conference Mix Paths 2 2 Total Mix Paths 32 32 32 Mix Paths Mix Paths mono equivalent Width Paths Note Main 1 PGM1 Paths Mono Stereo or 5 1 14 Pool of 14 Paths may be assigned...

Страница 83: ...DSP Paths 42 42 84 Mix Paths mono equivalent Main 1 PGM1 Paths 14 14 28 Main 2 PGM2 Paths Main 3 REC Paths Group Paths Aux Paths 8 8 16 PFL Mix Paths 2 2 4 AFL Mix Paths 2 2 4 Mix Minus Mix Paths 4 4...

Страница 84: ...hs 6 6 Mix Minus Mix Paths 4 4 Conference Mix Paths 2 2 Total Mix Paths 64 64 R80 Option 2 Console 1 Console 2 Totals 40 CH 40 CH DSP Paths mono equivalent Channel Paths 40 40 80 Aux Paths 16 16 32 Ma...

Страница 85: ...otal Mix Paths 48 32 32 112 64 Mix Paths Mix Paths mono equivalent Width Paths Note Main 1 PGM1 Paths Mono Stereo or 5 1 30 Pool of 30 Paths may be assigned as Mono Stereo or 5 1 Main 2 PGM2 Paths Mon...

Страница 86: ...oup Paths Aux Paths 16 16 PFL Mix Paths 6 6 AFL Mix Paths 6 6 Mix Minus Mix Paths 4 4 Conference Mix Paths 2 2 Total Mix Paths 64 64 R120 Option 2 Console 1 Console 2 Totals 60 CH 60 CH DSP Paths mono...

Страница 87: ...ivalent Channel Paths 80 40 120 Aux Paths 16 16 32 Main Group Paths 30 22 52 Total DSP Paths 126 78 204 Mix Paths mono equivalent Main 1 PGM1 Paths 30 22 52 Main 2 PGM2 Paths Main 3 REC Paths Group Pa...

Страница 88: ...32 24 8 3 32 20 20 20 32 24 8 Per Pack 96 60 60 60 96 72 24 1 64 44 44 44 64 48 16 2 32 20 20 20 32 24 8 Per Pack 96 64 64 64 96 72 24 1 48 32 32 32 48 24 12 2 24 16 16 16 24 24 6 3 24 16 16 16 24 24...

Страница 89: ...calrec com TYPE R SURFACE PANEL LAYOUT EXAMPLES...

Страница 90: ...h are not supplied with the switch 2 Cisco SG350 10 K9 10 port 8 2 switch Calrec 491 267 8 x 1Gbps RJ45 2 x combo RJ45 SFP 1Gbps slots that can accept 1Gbps interfaces Note that the use of the 2 x SFP...

Страница 91: ...91 EXAMPLE 1 12 FADER SURFACE...

Страница 92: ...92 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 2 18 FADER SURFACE...

Страница 93: ...93 EXAMPLE 3 24 FADER SURFACE...

Страница 94: ...94 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 4 TWO STUDIO INSTALLATION...

Страница 95: ...95...

Страница 96: ...96 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 5 THREE STUDIO INSTALLATION...

Страница 97: ...97...

Страница 98: ...98 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 5 THREE STUDIO INSTALLATION WITH REDUNDANT CORE...

Страница 99: ...99...

Страница 100: ...100 TYPE R Radio Production System Surface Panel Layout Examples EXAMPLE 6 SINGLE STUDIO INSTALLATION WITH REDUNDANT CORE...

Страница 101: ...calrec com TYPE R AOIP NETWORK EXAMPLES...

Страница 102: ...ber 491 268 4 All cabling shown is via RJ45 Cat5e shielded twisted pair STP cables Cisco and Artel Switch Management Settings for AoIP AES67 Networks Note Both the Cisco switch and the Artel ARG Quarr...

Страница 103: ...erface card fitted to Core TypeR Core Pri CONNECT Server AoIP 1 CH 1 256 A B AoIP 2 CH 257 512 A B A B 3 Type R Core with Calrec Connect stream management server installed 2 AoIP AES67 Interface cards...

Страница 104: ...s Type R Cores can be supplied without any AoIP Interfaces fitted in which case although the two pairs of AoIP connectors are fitted these will not be functional Optionally one or two AoIP Interfaces...

Страница 105: ...dicated audio network there is still additional traffic Higher channel counts can be achieved but deterministic network conditions are required to successfully exceed the safe working recommendations...

Страница 106: ...switches provide connections to end points and are interconnected by spine switches Each leaf needs a connection to each spine The following diagram shows the architecture of a Leaf and Spline network...

Страница 107: ...NGLE CORE WITH LOCAL I O 2 AOIP I O BOXES ON A NON PTP SWITCH EXAMPLE 3 SINGLE CORE WITH LOCAL I O 2 AOIP I O BOXES ON 2 REDUNDANT PTP SWITCHES Note In this case a single switch is being used for both...

Страница 108: ...E R Radio Production System AoIP Network Examples EXAMPLE 4 SINGLE CORE WITH LOCAL I O 4 AOIP BOXES ON 2 REDUNDANT PTP SWITCHES EXAMPLE 5 SINGLE CORE WITH LOCAL I O 10 AOIP BOXES ON 4 REDUNDANT PTP SW...

Страница 109: ...109 EXAMPLE 6 6 STUDIOS SINGLE CORE WITH LOCAL I O 12 AOIP I O BOXES ON 8 REDUNDANT PTP SWITCHES Note The dotted Links may be added to provide cable redundancy between switches...

Страница 110: ...110 TYPE R Radio Production System AoIP Network Examples EXAMPLE 7 6 STUDIOS MCR SINGLE CORES 2 AOIP CARDS CORE WITH LOCAL I O 20 AOIP I O BOXES ON 12 REDUNDANT SWITCHES...

Страница 111: ...111...

Страница 112: ...h keeps the Secondary Core in step with the Primary Core The link may be wired with a single cable or two for cable redundancy b The direct link between the A and B switches is to provide PTP sync Thi...

Страница 113: ...will not be available on the Redundant Secondary Core For I O signals where redundancy is required we recommend the use of networked Type R I O Boxes Connection Notes The direct link between the Prima...

Страница 114: ...I O 8 AOIP BOXES ON 8 REDUNDANT PTP SWITCHES I O Note In the event of a Redundant Secondary Core takeover any I O connected to the Primary Core local I O will not be available on the Redundant Second...

Страница 115: ...direct link between the Primary and Secondary Type R Cores is via the Core Surface connections which keeps the Secondary Core in step with the Primary Core The link may be wired with a single cable or...

Страница 116: ...WITH LOCAL I O 32 AOIP I O BOXES ON 12 REDUNDANT SWITCHES I O Note In the event of a Redundant Secondary Core takeover any I O connected to the Primary Core local I O will not be available on the Redu...

Страница 117: ...direct link between the Primary and Secondary Type R Cores is via the Core Surface connections which keeps the Secondary Core in step with the Primary Core The link may be wired with a single cable or...

Страница 118: ...S ON 12 REDUNDANT SWITCHES NOTE CONNECT SERVERS ARE INSTALLED ON PC S RATHER THAN CORES I O Note In the event of a Redundant Secondary Core takeover any I O connected to the Primary Core local I O wil...

Страница 119: ...direct link between the Primary and Secondary Type R Cores is via the Core Surface connections which keeps the Secondary Core in step with the Primary Core The link may be wired with a single cable or...

Страница 120: ...120 TYPE R Radio Production System AoIP Network Examples...

Страница 121: ...calrec com TYPE R SOFTWARE UPDATER...

Страница 122: ...connected PC type 172 16 255 40 into the address bar and press enter to navigate to the Software Updater landing page Note If Google Chrome is not installed navigate to https www google com chrome to...

Страница 123: ...guide Once updated create a new show and perform a full system power cycle Ensure the Recover LED on the front of the is either solid green or off before you do this Once power cycled ensure the recov...

Страница 124: ...on number in the file name 6 If a firmware version newer than the version installed on your system is available double click on it to download it to your PC 7 Navigate to the AoIP device web page agai...

Страница 125: ...calrec com TYPE R SPECIFICATIONS...

Страница 126: ...legs Monitor Inserts Dedicated Insert available to Console LS Studio1 LS and Misc LS Mix Minus Buses 2 Stereo Off Air Conference Bus 1 Stereo External Monitor Meter Inputs 48 VCA Groups Unlimited EQ...

Страница 127: ...ide to side to form bigger surfaces as long as clearance is provided below the units to provide the panels with sufficient ventilation Operating Ambient Air Temperature 0 C 40 C UR6500 Type R Core 240...

Страница 128: ...1U Rack is cooled by natural ventilation and does not require fan assistance having sufficient surface area to radiate heat adequately The side panels of the I O unit should be unobstructed with at le...

Страница 129: ...t from Type R I O units depends on the supply voltage and loading Typically it is 0 55 times the RMS VA Volts x Amperes at 230V and 0 7 times the RMS VA at 115V Heat output figures are available for a...

Страница 130: ...ne Inputs Distortion 1dBFS 1kHz Better than 0 005 86dB 20dBFS 1kHz Better than 0 003 90dB 40 dBFS 1kHz Better than 0 03 70dB Dynamic Range CCIR RMS 116dB Idle Channel Noise 116dBFS 88dBu Equivalent In...

Страница 131: ...RATE PROVISIONAL FIGURES From To Via Samples 48kHz 96kHz AES3 inputs SRC off AES3 Outputs Port to port 18 0 376ms 0 188ms AES3 Outputs channel group and aux or main output 30 0 626ms 0 313ms Analogue...

Страница 132: ...926 228 Iss 8 Calrec Audio Ltd Nutclough Mill Hebden Bridge West Yorkshire England UK HX7 8EZ Tel 44 0 1422 842159 Fax 44 0 1422 845244 Email Enquiries calrec com calrec com...

Отзывы: