6. Operation Panel Switch Functions
6.14 Handle Interruption
II
-23
6.14.4 Axis Movement Speed Resulting from Interruption
(1) The movement speed of the axis for which handle interruption is executed, may exceed the rapid
traverse feed rate during rapid traverse feed command (G00) processing in automatic start. To
prevent this, clamp the axis. (The movement speed equals Automatic-start movement speed +
Speed resulting from manual handle interruption.)
(2) The movement speed of the axis for which handle interruption is executed, may exceed the
cutting feed speed during cutting feed command (G01, G02, G03) processing in automatic start.
To prevent this, clamp the axis. (The movement speed equals Automatic start movement speed +
Speed resulting from manual handle interruption.)
(3) If, during automatic start, manual handle interruption is executed, in the same direction, for the
axis that is moving at an external decelerating speed, the axis movement speed may exceed the
external decelerating speed. To prevent this, clamp the axis. (The movement speed equals
Automatic start movement speed + Speed resulting from manual handle interruption.)
(4) If an attempt is made to execute interruption at a speed exceeding the clamp speed, the reading
on the handle scale does not match the distance of interruption.
(5) The handle scale factor depends on the selected input of the manual handle/step scale factor.