NV5100MC Master Control • Reference Man ual
111
6. Control Panels
FFCP
7 Transition buttons
The transition buttons include 2 groups: transition type, transition rate, and a larger orange but-
ton that initiates transitions. There are 5 transition types: cut, V-fade, cross-fade, cut-fade, and
fade-cut. There are 3 transition rates: slow, medium, and fast. (The actual rates are configured
in the current MCPM.)
8 System buttons.
The system buttons include 3 buttons: ‘Panel Lock’, ‘Automation Off’, and master ‘Fade to
Black’ by default. The configurer can redefine them.
9 “Layer” buttons
The layer section is a part of the program/ preset bus that allows you to combine video effects
and audio overs with your main source selections. The layer section includes keyers, logos, a
squeezeback generator, and audio “overs.” (Some MCPMs do not support all effects.)
FFCP Connectors
At the rear of the FFCP are 2 power connectors, one usable Ethernet connector, a ‘CP Aux’ connec-
tor, and a GPI/alarm connector. (See Figure 6-2 on page 109.)
Power
There are 2 AC connectors, PS1 and PS2, for the sake of redundancy. You need not use both if you
are not concerned with redundancy. The internal power supply modules include fans.
Ethernet
The FCP has one usable RJ-45 Ethernet port. The FFCP connects to the Ethernet switch on the
master control network. (The other RJ-45 port is not used.)
It is on this network that the FCP communicates with MCPMs and with the configuration software.
You (or your system administrator) must provide a unique IP address for the FFCP.
Without the IP address, the FFCP cannot communicate with either the MCPMs or the configuration
software. Use the Panel ID menu under the Panel Menu to set the IP address and IP subnet mask.
The default IP address is 192.168.7.100 and the subnet mask must always be 255.255.255.0.
GPI/Alarm
The FFCP has a DB25 connector that supports GPI inputs, GPI outputs, and alarms:
Refer to the GPI section in the appropriate control panel user’s guide for connection information.
See
GPI/Alarms
on page 188 for more information.
13
1
14
25
Minor Alarm
GPI In 1
unused
GPI Out 1
Major Alarm
unused
GPI Out 2
GPI In 2
11
23
10
COM
NO
NC
8
20
7
GND
+
5
17
4
COM
NO
NC
2
14
1
25
12
24
COM
NO
NC
22
9
21
19
6
18
GND
+
16
3
15
COM
NO
NC
Содержание NV5100MC Master Control
Страница 14: ...xiv Rev 2 10 17 Feb 11 Table of Contents ...
Страница 54: ...40 Rev 2 10 17 Feb 11 3 Frames Other Modules ...
Страница 92: ...78 Rev 2 10 17 Feb 11 4 MCPMs Other General Features ...
Страница 112: ...98 Rev 2 10 17 Feb 11 5 MCEs Summary ...
Страница 158: ...144 Rev 2 10 17 Feb 11 6 Control Panels Aux Preview GUI ...
Страница 166: ...152 Rev 2 10 17 Feb 11 7 Other MC Products Device Controller ...
Страница 224: ...210 Rev 2 10 17 Feb 11 C Misc Information NorthAmerican andInternational PowerCords ...
Страница 240: ...226 Rev 2 10 17 Feb 11 Index ...