8-98
8.8.2 Software Function Activation
The manufacturer provides activation codes for activating the functions listed in the table below. If
the customer needs to add any of the following functions, the after-sales service engineer can
apply to the manufacturer for the activation code.
Configuration Item
Function Description
PCV
Pressure control ventilation mode
PCV-VG
Pressure control ventilation-volume guarantee
SIMV-VC
Synchronized intermittent mandatory ventilation-volume control
SIMV-PC
Synchronized intermittent mandatory ventilation-pressure control
SIMV-VG
Synchronized intermittent mandatory ventilation-volume
guarantee
PS
Pressure support ventilation mode
CPAS/PS
Pressure support ventilation/continuous positive airway pressure
ventilation
Bypass CPB
mode
Spirometry Loop
8.8.2.1 Applying for Activation Codes
Note
To apply for activation codes, provide relevant information about the anaesthesia
machine for which functions are to be activated, including the machine ID, existing
configuration, and configuration to be activated.
When a customer needs to add pad configurations, the after-sales service engineer must apply to
the after-sales service department of Mindray for the corresponding activation codes. The
procedure is as follows:
1. Record the serial number (see the label on the left of the machine) of the anaesthesia
machine for which configurations are to be activated.
2. Record the machine ID and existing configurations. Choose
Main
>
System
>
Configuration
Information
to access the
Configuration Information
menu.
Содержание WATO EX-55Pro
Страница 1: ...WATO EX 55Pro 65Pro Anesthesia Machine Service Manual ...
Страница 2: ......
Страница 34: ...2 20 South African standard ...
Страница 48: ...2 34 VPM ...
Страница 139: ...4 39 b Gas Settings Press the Setup button select Setting ENTER Gas Settings MODIFY Gas Type O2 c Select BACK BACK BACK ...
Страница 142: ...4 42 ...
Страница 144: ...4 44 b Gas Settings Press the Setup button select Setting ENTER Gas Settings MODIFY Gas Type O2 c Select BACK BACK BACK ...
Страница 196: ...6 26 FOR YOUR NOTES ...
Страница 213: ...7 17 2 Zero the sensor without connecting any tubes 3 User Setup Gas Type O2 4 User Setup Measure Mode BTPS ...
Страница 288: ...8 34 Test fixture of the vaporizer support Anesthesia machine calibration device 1 MPa 10 bar test pressure gauge ...
Страница 356: ...8 102 FOR YOUR NOTES ...
Страница 396: ...9 40 2 Remove the two ends of the breathing tubes from the inspiration expiration connectors on the breathing system ...
Страница 438: ...9 82 FOR YOUR NOTES ...
Страница 440: ...10 2 10 3 Diagrams and Tables 24 17 16 7 6 5 3 2 18 20 25 1 4 23 21 22 15 14 13 12 11 10 9 8 26 19 ...
Страница 447: ...10 9 10 3 2 Hardware Box 2 4 3 5 7 8 6 12 9 10 13 14 15 1 11 ...
Страница 449: ...10 11 ...
Страница 455: ...10 17 10 3 5 WATO EX 55 Pro 65 Pro Cart Assembly ...
Страница 457: ...10 19 10 3 6 WATO EX 55 Pro 65 Pro Pre pak Circuit Bracket Assembly ...
Страница 462: ...10 24 4 3 1 2 ...
Страница 473: ......
Страница 474: ...PN 046 009688 00 4 0 ...