9-76
9.5.1.2 Board List
S/N Description
P/N
B1
0623 motherboard PCBA
051-000765-02
B2
0621 electronic flowmeter PCBA
0621-30-69351 (three flowtubes
configured)
0621-30-78639 (two flowtubes
configured)
0621-30-78638 (one flowtube
configured)
B3
0623 toplight board PCBA
051-000764-00
B4
0616 monitored signal detection board
051-003166-00
B5
0621 power board
0621-30-78595
B6
0621 main control board
9210-30-30150
B7
0623 battery conversion board PCBA
051-000768-00
B8
0623 key control conversion board PCBA
051-000766-00
B9
0623 alarm lamp board PCBA
051-000767-00
B10
Touchscreen control board
6800-30-50082
B11
Copper axis encoder board
0010-30-43089
B12
0621 infrared backlight board
051-000259-00
B13
Network interface board
9210-30-30152
B14
0621 valve drive board
0621-30-78634
B15 0616
isolation
transformer drive board
051-000036-00
K1
AC power socket
/
K2 Lithium
battery
/
K3
Hardware box radiator fan
/
K4 System
switch
/
K5
Module rack fan
/
K6 CIS
system
/
K7 10.4"
inverter
/
K8 12.1"
inverter
/
K9 10.4"
display
/
K10 12.1"
display
/
K11 Speaker
/
K12
Three-level mechanical switch
/
K13 Three-way
valve
/
K14 Heater
/
K15
O2 flush button
/
K16
Pneumatic block pressure switch
/
K17 ACGO
travel
switch
/
K18
O2 pressure switch at gas supply inlet
/
K19 O2
sensor
/
Содержание WATO EX-55Pro
Страница 1: ...WATO EX 55Pro 65Pro Anesthesia Machine Service Manual ...
Страница 2: ......
Страница 34: ...2 20 South African standard ...
Страница 48: ...2 34 VPM ...
Страница 139: ...4 39 b Gas Settings Press the Setup button select Setting ENTER Gas Settings MODIFY Gas Type O2 c Select BACK BACK BACK ...
Страница 142: ...4 42 ...
Страница 144: ...4 44 b Gas Settings Press the Setup button select Setting ENTER Gas Settings MODIFY Gas Type O2 c Select BACK BACK BACK ...
Страница 196: ...6 26 FOR YOUR NOTES ...
Страница 213: ...7 17 2 Zero the sensor without connecting any tubes 3 User Setup Gas Type O2 4 User Setup Measure Mode BTPS ...
Страница 288: ...8 34 Test fixture of the vaporizer support Anesthesia machine calibration device 1 MPa 10 bar test pressure gauge ...
Страница 356: ...8 102 FOR YOUR NOTES ...
Страница 396: ...9 40 2 Remove the two ends of the breathing tubes from the inspiration expiration connectors on the breathing system ...
Страница 438: ...9 82 FOR YOUR NOTES ...
Страница 440: ...10 2 10 3 Diagrams and Tables 24 17 16 7 6 5 3 2 18 20 25 1 4 23 21 22 15 14 13 12 11 10 9 8 26 19 ...
Страница 447: ...10 9 10 3 2 Hardware Box 2 4 3 5 7 8 6 12 9 10 13 14 15 1 11 ...
Страница 449: ...10 11 ...
Страница 455: ...10 17 10 3 5 WATO EX 55 Pro 65 Pro Cart Assembly ...
Страница 457: ...10 19 10 3 6 WATO EX 55 Pro 65 Pro Pre pak Circuit Bracket Assembly ...
Страница 462: ...10 24 4 3 1 2 ...
Страница 473: ......
Страница 474: ...PN 046 009688 00 4 0 ...