RS232
: Uses the OIT’s 9-pin female connector labeled
PLC[RS232]
.
w
The following selections use the OIT’s 9-pin male connector labeled
PLC[RS485]
PC[RS232]
.
RS485 default:
The selected protocol determines 2 or 4 wire.
RS485 4W:
Forces RS485 4-wire configuration.
RS485 2W:
Forces RS485 2-wire configuration.
Ethernet:
Uses the RJ45 10BaseT connector.
4.
Select
baud rate
,
parity,
data bits
, and
stop bits
. Use Maple Systems’ Controller Information
Sheets or the PLC manufacturer’s operations manual for information on the communications
parameters required by the PLC. These parameters have to match the PLC settings.
5.
Parameter 1 and 2 are used to configure a delay time for the OIT. The time set on these
parameters is the time the OIT will wait before sending another request for information.
Parameter 1 is used in the Protocol level and Parameter 2 is used at the Operating System
level. Refer to the Controller Information Sheets if these parameters are required. Parameters
3-6 are not used.
6.
Set the
OIT Station No
. used by some protocols that require the OIT to have a unique network
address. Consult your Controller Information Sheets for information on the protocols to
which this parameter applies.
7.
Set the
PLC Station Number
or
Node Address
of the PLC with which the OIT will
communicate.
8.
Multiple HMI and HMI-HMI link speed:
Used when connecting multiple OITs to a single
PLC. Disable this setting if you are connecting only a single OIT to a PLC. For more
information on connecting multiple OITs, see
Connecting Multiple OITs to one PLC
at the
end of this chapter.
9.
Connect I/F:
Allows selection of the method by which multiple OITs can be daisy-chained.
The options are
Serial
or
Ethernet
. If
Ethernet
is selected, configure the
Local
and the
Server
IP addresses
. For more information, see
Connecting Multiple OITs Using the Ethernet Port
at the end of this chapter.
10
PLC Block Pack:
Determines how many words are read from the PLC in one
communication cycle. For more information on this feature, see
PLC Block Pack
at the end
of this chapter.
1010-1001a, Rev 02
60
Sil ver Se ries In stal la tion & Op er a tion Man ual
Содержание Silver HMI504T
Страница 1: ...1010 1001A Rev 02...
Страница 20: ...1010 1001a Rev 02 16 Silver Series Installation Operation Manual OIT to PC Serial Port Pin Assignments...
Страница 32: ...1010 1001a Rev 02 28 Silver Series Installation Operation Manual...
Страница 128: ...1010 1001a Rev 01 124 Silver Series Installation Operation Manual...
Страница 156: ...1010 1001a Rev 02 152 Silver Series Installation Operation Manual...
Страница 166: ...1010 1001a Rev 02 162 Silver Series Installation Operation Manual...
Страница 216: ...1010 1001a Rev 01 212 Silver Series Installation Operation Manual...
Страница 251: ...1010 1001a Rev 02 Macros 247 Set Bit Objects Attributes Dialog Project Example of Add 2...
Страница 264: ...End Macro_Command 1010 1001a Rev 02 260 Silver Series Installation Operation Manual...
Страница 268: ...1010 1001a Rev 01 264 Silver Series Installation Operation Manual...