4
To edit the System Parameters
1.
Click the
Edit
menu on the main screen of EasyBuilder.
2.
At the bottom of the menu, click
System Parameters
. The Set System Parameters dialog box
appears.
3.
The dialog box has six tabs: PLC, General, Indicator, Security, Editor and Hardware. Select
the
PLC
tab.
4.
Select the PLC that you are using or
MemoryMap_Master
from the PLC type pull-down
box.
5.
Select
RS485
from the Serial port I/F box.
6.
Select
8 bits
from the Data bits box.
7.
Select
1 bit
from the Stop bits box.
8.
Select
19200
from the Baud rate box.
9.
Select
Odd
from the Parity box.
10. Select
0
for the OIT station No. and PLC station No. Boxes.
11. Select
Disable
from the Multiple OIT box.
12. Select
3.0
from the PLC time out constant box.
13. Select
0
from the PLC block pack box.
14. Now click on the
General
tab.
15. Select
10
for the Startup window No. Box.
16. Click
OK
to return to the EasyBuilder main screen.
The communications parameters selected above were selected at random. Please enter
the PLC type and communications parameters that match your PLC. For more
information, consult your PLC operations manual or Maple Systems Controller
Information Sheets available on our website at www.maple-systems.com .
Cre ating a Startup Win dow
We will configure Window #10 as the startup screen. The OIT can store up to 1999 predefined windows but
screens 0-9 are reserved. Therefore, the first window screen that is available for configuration is Window #10. By
default, this is the startup screen when you begin a new project. This section will show how to place text in the
window and how to create two function keys that will open and close Window #11.
4
To place text on Window#10
1.
From the Draw menu, click
Text
. The Create Text Object dialog box appears.
2.
Click the pull down box from the Color box. The Color dialog box appears.
3.
Click on the white color box, then click
OK
. The color box should reflect the color that you
have chosen.
4.
Select
16
in the Font box.
5.
Select
Left
in the Align box.
6.
Double-click the word ‘text’ in the Content box and type “
This is the Startup Screen!
.”
7.
Click
OK
.
8.
On the main screen of EasyBuilder, you will see a white rectangle outline that is attached to
your cursor in the work area. This represents the text box just created. Center the rectangle
somewhere on the top third portion of the work area and then click. The text box “This is the
Startup Screen!” should appear.
4
To create a function key on Window#10
1.
From the Parts menu, click
Function Key
. The Create Function Key Object dialog box
appears.
2.
Type
On Button
in the Description box.
3.
Click Popup Window.
4.
Type
11
in the Window No. Box.
5.
Click the
Shape
tab.
6.
Click
Use shape
, then click
Shape library
. The Shape Library dialog box appears.
1010-1001a, Rev 02
20
Sil ver Se ries In stal la tion & Op er a tion Man ual
Содержание Silver HMI504T
Страница 1: ...1010 1001A Rev 02...
Страница 20: ...1010 1001a Rev 02 16 Silver Series Installation Operation Manual OIT to PC Serial Port Pin Assignments...
Страница 32: ...1010 1001a Rev 02 28 Silver Series Installation Operation Manual...
Страница 128: ...1010 1001a Rev 01 124 Silver Series Installation Operation Manual...
Страница 156: ...1010 1001a Rev 02 152 Silver Series Installation Operation Manual...
Страница 166: ...1010 1001a Rev 02 162 Silver Series Installation Operation Manual...
Страница 216: ...1010 1001a Rev 01 212 Silver Series Installation Operation Manual...
Страница 251: ...1010 1001a Rev 02 Macros 247 Set Bit Objects Attributes Dialog Project Example of Add 2...
Страница 264: ...End Macro_Command 1010 1001a Rev 02 260 Silver Series Installation Operation Manual...
Страница 268: ...1010 1001a Rev 01 264 Silver Series Installation Operation Manual...