Place these objects onto the screen as shown:
4
Create an Event Log object to monitor alarms
1.
From the
Parts
menu, click
Event Log
. Or click the
Event Log
icon in the Draw toolbar.
The Event Log Object dialog box appears.
2.
Enter the following parameters for each event:
Attribute
Setting
Address type:
Bit
Read Address
LB0 to LB4
Event trig
On
Text
Water Level Low! (LB0)
Fuel Level Low! (LB1)
Coolant Level Low! (LB2)
Pump Motor Fault! (LB3)
Pump Motor Overload! (LB4)
Font:
16
Color:
Select any color
Write value:
0
3.
Click
OK
. The entries should look like this:
1010-1001a, Rev 02
236
Sil ver Se ries In stal la tion & Op er a tion Man ual