windows may require a common alarm message. By changing the common window with each series of windows,
you can customize each common window to contain only the graphics objects that are needed.
4
To change the active common window
1.
Create a common window.
2.
Create a base window that is full screen. This will be used as another common window.
Note that when a base window is used as a common window, the
Start Pos:
,
Style
,
Frame
,
and
Background
settings are ignored by the OIT. For this example, let’s use Window#30 as
the alternate common window.
3.
Create another full screen base window that can be displayed along with the common
windows, (such as a startup window). Let’s use Window#10, the initial window, for our
example.
4.
On Window#10, create a Function Key object that is used to change the common window.
From the
Parts
menu, click
Function Key
. The Create Function Key Object dialog box
appears.
5.
On the General tab, click Change Common Window.
6.
In the same frame, enter
30
for
Window No
..
7.
Click the
Shape
tab. Click
Use Shape
. Click on the
Shape Library…
command. Select
Shape#0
from the
button1
library. Click
OK
to return to the Create Function Key Object
dialog box.
8.
Click the
Label
tab. Click the
Use label
checkbox.
9.
For our example, type
CCW
(meaning
C
hange
C
ommon
W
indow) into the
Contents
box.
Click
OK
to exit the Create Function Key Object dialog box and go back to the EasyBuilder
main screen.
10. Place the new Function Key object somewhere on Window #10.
Below is an illustration of what the default common window, Window#30 (alternate common window), and
Window#10 (startup window) might look like:
Default Common
Window #30
Window #10
1010-1001a, Rev 02
Cre ating Win dows
107
Содержание Silver HMI504T
Страница 1: ...1010 1001A Rev 02...
Страница 20: ...1010 1001a Rev 02 16 Silver Series Installation Operation Manual OIT to PC Serial Port Pin Assignments...
Страница 32: ...1010 1001a Rev 02 28 Silver Series Installation Operation Manual...
Страница 128: ...1010 1001a Rev 01 124 Silver Series Installation Operation Manual...
Страница 156: ...1010 1001a Rev 02 152 Silver Series Installation Operation Manual...
Страница 166: ...1010 1001a Rev 02 162 Silver Series Installation Operation Manual...
Страница 216: ...1010 1001a Rev 01 212 Silver Series Installation Operation Manual...
Страница 251: ...1010 1001a Rev 02 Macros 247 Set Bit Objects Attributes Dialog Project Example of Add 2...
Страница 264: ...End Macro_Command 1010 1001a Rev 02 260 Silver Series Installation Operation Manual...
Страница 268: ...1010 1001a Rev 01 264 Silver Series Installation Operation Manual...