To create a MultiState Switch Object
1.
From the
Parts
menu, click
MultiState Switch
. Or click the
MultiState Switch
icon in the
Part1 toolbar. The Create MultiState Switch Object dialog box appears.
2.
Use the
Description:
box to enter a title for the MultiState Switch part. A description is not
necessary but does help you identify the purpose of the part.
3.
In the
Read address
frame, select the 16-bit PLC register or OIT internal memory address
that the part continuously reads. You can select
BIN
(binary) or
BCD
format.
4.
In the
Write address
frame, select the 16-bit PLC register or OIT internal memory address
that the part writes to when pressed. You can select
BIN
(binary) or
BCD
format.
5.
In the
Attribute
frame, select how you want the MultiState Switch object to operate:
Switch Style
Option
Description
JOG+
Increments the PLC register by 1 each time the key is pressed. When the highest state is
reached, the key resets to State 0.
No. of states:
Range: 1 to 32
JOG-
Decrements the PLC register by 1 each time the key is pressed. When the State 0 is
reached, the key resets to the highest state.
No. of states:
Range: 1 to 32
6.
Refer to the Bit Lamp Object section for information on using the
Shape
tab.
7.
Refer to the Bit Lamp Object section for information on using the
Label
tab.
8.
Click
OK
. The Create MultiState Switch Object form closes and the main screen of
EasyBuilder appears with the cursor tied to a rectangular outline of the part you just created at
the upper left corner of the screen. Move the part to the desired location on the window.
9.
Once the part is placed onto the window, you can adjust the location of the label inside the
part by clicking once on the label. This will highlight the entire object. Now click on the
1010-1001a, Rev 02
Rep re senting Data with Graph ics Ob jects
183
Содержание Silver HMI504T
Страница 1: ...1010 1001A Rev 02...
Страница 20: ...1010 1001a Rev 02 16 Silver Series Installation Operation Manual OIT to PC Serial Port Pin Assignments...
Страница 32: ...1010 1001a Rev 02 28 Silver Series Installation Operation Manual...
Страница 128: ...1010 1001a Rev 01 124 Silver Series Installation Operation Manual...
Страница 156: ...1010 1001a Rev 02 152 Silver Series Installation Operation Manual...
Страница 166: ...1010 1001a Rev 02 162 Silver Series Installation Operation Manual...
Страница 216: ...1010 1001a Rev 01 212 Silver Series Installation Operation Manual...
Страница 251: ...1010 1001a Rev 02 Macros 247 Set Bit Objects Attributes Dialog Project Example of Add 2...
Страница 264: ...End Macro_Command 1010 1001a Rev 02 260 Silver Series Installation Operation Manual...