2.
Click the
Add...
button. The Data Transfer Object dialog box appears.
3.
Use the
Description:
box to enter a title for the Data Transfer part. A description is not
necessary but does help you identify the purpose of the part.
4.
In the
Source address
frame, select the PLC coils or registers that are to be copied. If the
Address mode
is Word, then the
No. of words
box is used to specify the total number of
16-bit registers to copy. The range is 1 to 16.
5.
In the
Destination address
frame, select the PLC coils or registers that receive the data.
6.
In the
Attribute
frame, for the
Address mode:
setting click
Word
or
Bit
. Use the Word
setting for data transfer of 16-bit registers. Use the Bit for data transfer of coils. If Bit is
selected, enter the total number of bits that are to be transferred in the
Number of bits:
box.
The range is 1 to 255.
7.
The
Interval:
setting in the
Attribute
frame, is used to select the period at which the data is
transferred. Select 0 for continuous data transfer. Range is 0 to 25.5 seconds in 0.1 second
increments. Note that selecting a smaller period will decrease the amount of OIT processing
time that can be allocated to other tasks.
8.
Click
OK
to close the Data Transfer Object’s Attributes dialog box. The Data Transfer
Object dialog box reappears with the new entry listed. You can edit the attributes of an
existing Data Transfer object by clicking on the
Setting...
button. Any entries can be deleted
by clicking on the
Delete
button.
9.
Click
Close
to close the Data Transfer Object dialog box. The Data Transfer Object is active
no matter what windows are currently displayed on the OIT screen. Therefore, you do not
have to place the object onto a window screen.
Using the Rec ipe Trans fer Ob ject
The Recipe Transfer Object is used to download or save data from one or more PLC registers to the OIT’s internal
registers that are reserved for recipes. This occurs when the object is activated by a press from the OIT operator.
Each Object created can transfer from 1-32767 continuous registers.
Recipes are not available in the HMI504T.
1010-1001a, Rev 02
240
Sil ver Se ries In stal la tion & Op er a tion Man ual
Содержание Silver HMI504T
Страница 1: ...1010 1001A Rev 02...
Страница 20: ...1010 1001a Rev 02 16 Silver Series Installation Operation Manual OIT to PC Serial Port Pin Assignments...
Страница 32: ...1010 1001a Rev 02 28 Silver Series Installation Operation Manual...
Страница 128: ...1010 1001a Rev 01 124 Silver Series Installation Operation Manual...
Страница 156: ...1010 1001a Rev 02 152 Silver Series Installation Operation Manual...
Страница 166: ...1010 1001a Rev 02 162 Silver Series Installation Operation Manual...
Страница 216: ...1010 1001a Rev 01 212 Silver Series Installation Operation Manual...
Страница 251: ...1010 1001a Rev 02 Macros 247 Set Bit Objects Attributes Dialog Project Example of Add 2...
Страница 264: ...End Macro_Command 1010 1001a Rev 02 260 Silver Series Installation Operation Manual...
Страница 268: ...1010 1001a Rev 01 264 Silver Series Installation Operation Manual...