4 - 2 4
Lucent Technologies
365-575-925R1.5
Issue 1, April 2002
Step 3
The following table shows example settings for each item under the under the
RIP General
Parameters
menu. Remember to configure the RIP parameters on both OptiStar EdgeSwitches.
OptiStar EdgeSwitch A
OptiStar EdgeSwitch B
a.
RIP Version
2
2
b.
RIP Administration Status
Enabled
Enabled
c.
Supplier Mode
Supplier
Supplier
d.
Border Gateway Filtering
Enabled
Enabled
e.
Act as a Gateway?
Yes
Yes
f.
Multicast/Broadcast
Broadcast
Broadcast
a.
Select the
RIP Version
Number (1 or 2) that you will be running. Both switches should be set
to run the same version. The default value is Version
2
.
b.
Set the
RIP Administration Status
to
Enable
.
Note:
RIP will
not
run on the switch if this
parameter is disabled. The default value is
ENABLE
.
c.
Select the
Supplier Mode
(either Supplier or Listener).
The default value is
SUPPLIER
.
d.
Turn Border Gateway Filtering on (Enable) or off (Disable).
The default value is
ENABLE
.
e.
Select whether the switch should
Act as gateway?
The default value is
Yes (RIP_GATEWAY)
.
f.
Select
Multicast
or
Broadcast
mode.
The default value is
BROADCAST
.
Step 2
To verify that you have the desired
RIP General Parameter
settings, from the main menu follow the
path:
[1] Operational Information & Status
→
→
→
→
[7] Routing Information
→
→
→
→
[3] RIP Parameters
→
→
→
→
[1]
RIP General Parameters
Step 3
The next step is to enable RIP routing on the selected ports. Go back to the
RIP Parameters
menu
(from the main menu follow the path:
[3] Configuration
→
→
→
→
[6] Routing Configuration
→
→
→
→
[5] Set
RIP Parameters
) and select:
[2] Set RIP Interface Status
Enter a Slot Number (1-4) and a Port Number (1 or 2) to add a port as a RIP Interface. Select
1
to
Enable
. Repeat this step for each port that will be designated to use RIP.
Note:
You
must
enable the RIP Interface for each port that is designated to use RIP.
Step 4
To verify that you have the desired Interface Status for each port on the OptiStar EdgeSwitch, from
the main menu follow the path:
[1] Operational Information & Status
→
→
→
→
[7] Routing
Information
→
→
→
→
[3] RIP Parameters
→
→
→
→
[2] RIP Interface Status
Step 5
In order for the new configuration to take effect, you must restart the OptiStar EdgeSwitch. From the
main menu follow the path:
[3] Configuration
→
→
→
→
[2] System Information
→
→
→
→
[7] Reset OptiStar EdgeSwitch
Содержание OptiStar EdgeSwitch
Страница 4: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 20: ...x v i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 26: ...x x i i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 27: ...Product Overview 365 575 925R1 5 Lucent Technologies 1 1 Issue 1 April 2002 CHAPTER 1 Product Overview...
Страница 62: ...3 1 2 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS LEFT INTENTIONALLY BLANK...
Страница 178: ...5 6 4 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 274: ...7 1 0 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 275: ...Troubleshooting 365 575 925R1 5 Lucent Technologies 8 1 Issue 1 April 2002 CHAPTER 8 Troubleshooting...
Страница 281: ...Contacting Lucent 365 575 925R1 5 Lucent Technologies 9 1 Issue 1 April 2002 CHAPTER 9 Contacting Lucent...
Страница 283: ...Appendices 365 575 925R1 5 Lucent Technologies A P 1 Issue 1 April 2002 APPENDICES...
Страница 324: ......