OptiStar EdgeSwitch Configuration
365-575-925R1.5
Lucent Technologies
4 - 2 3
Issue 1, April 2002
Step 1
To assign IP addresses and subnet masks to each port, follow the menu path:
[3] Configuration
Æ
Æ
Æ
Æ
[4] IP Parameters
Æ
Æ
Æ
Æ
[3] Set Switching Port IP Address & Mask
The following table gives an example of how to assign the Switching Interface (port) IP addresses
and subnet masks. Remember that in order to set up routing between 2 EdgeSwitches, you must
assign the network-linked port on each EdgeSwitch to the same IP subnetwork.
OptiStar EdgeSwitch A
OptiStar EdgeSwitch B
Module Type
OC-48c
Gigabit Ethernet
OC-48c
Gigabit Ethernet
Slot Number
1
2
1
2
Port Number
1
1
2
1
1
2
IP Address per Port
192.168.3.100 192.168.5.100 192.168.6.100 192.168.3.200 192.168.7.100 192.168.8.100
Subnet Mask
255.255.255.0 255.255.255.0 255.255.255.0 255.255.255.0 255.255.255.0 255.255.255.0
In the given example, the OC-48c module on EdgeSwitch A (Slot 1, Port 1) is in the same subnet
(192.168.3.0) as the OC-48c module on EdgeSwitch B (Slot 1, Port 1).
Step 2
Once you have assigned IP addresses and subnet masks to the desired ports, it is recommended that
you verify IP connectivity between the ports that you have set up to be on the same IP subnet. To use
the OptiStar EdgeSwitch Ping Utility to verify IP connectivity, from the main menu of the CLI,
follow the path:
[5] Utilities
→
→
→
→
[1] Ping Utility
Step 3
Ping the connected port on the remote OptiStar EdgeSwitch by entering the IP address that was
assigned to that port. (In the example given above: using the CLI’s Ping Utility on OptiStar
EdgeSwitch A, enter the IP address of the OC-48c port on OptiStar EdgeSwitch B, which is
192.168.3.200.)
4.7.2 RIP Routing
Step 1
Before you set up routing, ensure that: (1) the IP network between your OptiStar EdgeSwitches is set
up properly, and (2) there is IP connectivity between the ports for which you plan to configure
routing (
see Section 4.6
).
Step 2
To set up RIP routing between Network Modules, from the main menu follow the path:
[3] Configuration
→
→
→
→
[6] Routing Configuration
→
→
→
→
[5] Set RIP Parameters
→
→
→
→
[1] Set RIP
General Parameters
Содержание OptiStar EdgeSwitch
Страница 4: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 20: ...x v i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 26: ...x x i i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 27: ...Product Overview 365 575 925R1 5 Lucent Technologies 1 1 Issue 1 April 2002 CHAPTER 1 Product Overview...
Страница 62: ...3 1 2 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS LEFT INTENTIONALLY BLANK...
Страница 178: ...5 6 4 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 274: ...7 1 0 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 275: ...Troubleshooting 365 575 925R1 5 Lucent Technologies 8 1 Issue 1 April 2002 CHAPTER 8 Troubleshooting...
Страница 281: ...Contacting Lucent 365 575 925R1 5 Lucent Technologies 9 1 Issue 1 April 2002 CHAPTER 9 Contacting Lucent...
Страница 283: ...Appendices 365 575 925R1 5 Lucent Technologies A P 1 Issue 1 April 2002 APPENDICES...
Страница 324: ......