4.3 Setting Up Security
4.3.1 Setting the Admin User Password
Now you will need to set up a password for the System Administrator (also referred to as the Admin User, or
super user). The Admin User is the only person who can modify the Administrator user name and password.
Note:
For security purposes, this function is not available via Web-based Management.
If you have already filled out the
OptiStar™ EdgeSwitch Basic Configuration Worksheet
provided in
Appendix
A
during the planning phase of your installation, you will want to refer to it as you continue through the
configuration steps provided in this chapter. If you have not filled out the worksheet, you may wish to do so
now, since it is an effective tool for summarizing and maintaining the information you will need to configure the
OptiStar EdgeSwitch.
Step 1
To set the Admin User Password, from the main menu follow the path:
[4] Administration
→
→
→
→
[1] Authentication Information
→
→
→
→
[2] Modify Admin UserName,
Password
Step 2
Once this option is selected from the
Authentication Information
menu, the following prompts will
be displayed (in succession):
Enter Old Administrator UserName
:
Enter the current user name. (The default user name is
optistar
.)
Enter Old Administrator Password
:
Enter the current password. (The default password is
optistar
.)
Step 3
Next, if the user name and password entered in
Step 2
were correct, the following prompts will be
displayed (in succession).
If the user name and password have not been changed from the defaults,
you should change them now.
Enter New Administrator UserName
:
Enter a new user name that is a minimum of 6 and a maximum of 8 alpha-numeric characters in
length. If you enter a user name that is less than 6 characters or greater than 8 characters, you will
receive an error message.
Enter New Administrator Password
:
Enter a new password that is a minimum of 6 and a maximum of 8 alpha-numeric characters in
length. If you enter a password that is less than 6 characters or greater than 8 characters, you will
receive an error message
.
Re-Enter New Administrator Password :
Re-enter the new password.
Содержание OptiStar EdgeSwitch
Страница 4: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 20: ...x v i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 26: ...x x i i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 27: ...Product Overview 365 575 925R1 5 Lucent Technologies 1 1 Issue 1 April 2002 CHAPTER 1 Product Overview...
Страница 62: ...3 1 2 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS LEFT INTENTIONALLY BLANK...
Страница 178: ...5 6 4 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 274: ...7 1 0 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 275: ...Troubleshooting 365 575 925R1 5 Lucent Technologies 8 1 Issue 1 April 2002 CHAPTER 8 Troubleshooting...
Страница 281: ...Contacting Lucent 365 575 925R1 5 Lucent Technologies 9 1 Issue 1 April 2002 CHAPTER 9 Contacting Lucent...
Страница 283: ...Appendices 365 575 925R1 5 Lucent Technologies A P 1 Issue 1 April 2002 APPENDICES...
Страница 324: ......