4 - 2 0
Lucent Technologies
365-575-925R1.5
Issue 1, April 2002
Under Option
[2] Set Switching Port Subnet Mask
, the following prompts will be displayed in
succession:
Enter Switching Module Number (1-4) :
Enter Switching Port Number (1-2)
:
Enter Switching Port Subnet Mask :
Note:
All of the IP addresses in the same port group must be on the same IP subnetwork. The IP
address of the first port in the group will be designated as the default gateway for this bridge group.
In this example, Module 2/Port 1 is the designated default gateway.
Assign an IP address to the first port in the group by following the prompts under Option
[1] Set
Switching Port IP Address
. Repeat this procedure for every port in the group. Then assign a subnet
mask to the first port in the group by following the prompts under Option
[2] Set Switching Port
Subnet Mask
. Repeat this procedure for every port in the group. Refer to the diagram on
Slot
Numbering in Section 3.4.1
for help in determining correct module and port numbers.
Step 8
To verify that the you have entered the IP addresses and subnet masks correctly, you may view the
Switching Ports IP Address Table
. From the main menu follow the path:
[1] Operational Information & Status
→
→
→
→
[4] IP Parameters
→
→
→
→
[3] Switching Ports IP Address
Step 9
Once all of the IP addresses and subnet masks are entered, continue on to the next section, entitled
“
Setting up a Static Route and Checking IP Connectivity
”.
4.6 Setting up a Static Route and Checking IP Connectivity
Step 1
To set up a static route, from the main menu follow the path:
[3] Configuration
→
→
→
→
[6] Routing Configuration
→
→
→
→
[1] Set Static Route
At the
Enter Destination IP Address
: prompt, enter the IP address of the remote destination.
At the
Enter Subnet Mask:
prompt, enter the subnet mask of the remote destination.
At the
Enter Next Hop IP address:
prompt
,
enter the IP address of the gateway to the remote
destination.
Step 2
To view the configured static route, from the main menu follow the path:
[1] Operational Information & Status
→
→
→
→
[7] Routing Information
→
→
→
→
[2] Static Routes
Step 3
Repeat Step (1) at the remote destination, as well as at every hop along the route.
Step 4
To check for IP connectivity, first look at Routing Table to determine the IP address(es) of the
systems that should have IP connectivity to the OptiStar EdgeSwitch. To view the Routing Table,
from the main menu follow the path:
[1] Operational Information & Status
→
→
→
→
[7] Routing Information
→
→
→
→
[1] Routing Table
Step 5
Next, it is recommended that you verify IP connectivity between the ports that you have set up to be
on the same IP subnetwork. To use the OptiStar EdgeSwitch Ping Utility to verify IP connectivity,
from the main menu of the CLI, follow the path:
[5] Utilities
→
→
→
→
[1] Ping Utility
Содержание OptiStar EdgeSwitch
Страница 4: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 20: ...x v i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 26: ...x x i i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 27: ...Product Overview 365 575 925R1 5 Lucent Technologies 1 1 Issue 1 April 2002 CHAPTER 1 Product Overview...
Страница 62: ...3 1 2 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS LEFT INTENTIONALLY BLANK...
Страница 178: ...5 6 4 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 274: ...7 1 0 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 275: ...Troubleshooting 365 575 925R1 5 Lucent Technologies 8 1 Issue 1 April 2002 CHAPTER 8 Troubleshooting...
Страница 281: ...Contacting Lucent 365 575 925R1 5 Lucent Technologies 9 1 Issue 1 April 2002 CHAPTER 9 Contacting Lucent...
Страница 283: ...Appendices 365 575 925R1 5 Lucent Technologies A P 1 Issue 1 April 2002 APPENDICES...
Страница 324: ......