Detailed FCIP Network Module CLI Reference Guide
365-575-925R1.5
Lucent Technologies
6 - 7
Issue 1, April 2002
Description
There are nine Fault LED severity levels that can be selected. The Fault LED Severity is tripped by messages at
the set severity level or higher. The
Fault LED
is triggered over the following conditions
:
•
Internal FCIP Network Module failure – an internal failure was detected
•
Self test failure - The POST test failed and the system needs attention.
•
Incorrect configuration loaded
The nine possible levels are described as follows:
Fault LED Severity Levels
Description
[0] emergency
Immediate action required; system failing
[1] alert
Unrecoverable condition reported; major event in progress
[2] critical
Event failed with possible loss of integrity
[3] error
Condition failed; action required
[4] warning
Failed event occurred; no action required
[5] notify
Configuration error or abnormal event occurred; no action required
[6] info
Event occurred; no action required
[7] debug
Internal message for development
[8] mark
Message marker
The existing level is displayed in brackets at the prompt (in this example the severity level is set to
[2] critical
):
Fault LED Severity [2] =
Press the <
Enter
> key to keep the current setting, or enter a new setting after the equal sign, then press the
<
Enter
> key. The display will show OK, indicating the new setting has been accepted.
6.1.2.6 Clear Event Log
Menu Path:
1) config
→
2) event
→
6) clear_log
Shortcut Command:
At the root menu, type
config event clear_log
Description
This menu item allows the user to clear the current event log (i.e. delete all events messages that are stored on
the FCIP Network Module). The FCIP Network Module will continue to generate event messages as they occur.
Do you wish to continue (Yes / No): [
N
]
Press the <
Enter
> key to keep the event messages, or type a
Y
, then press the <
Enter
> key to clear the log.
Содержание OptiStar EdgeSwitch
Страница 4: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 20: ...x v i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 26: ...x x i i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 27: ...Product Overview 365 575 925R1 5 Lucent Technologies 1 1 Issue 1 April 2002 CHAPTER 1 Product Overview...
Страница 62: ...3 1 2 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS LEFT INTENTIONALLY BLANK...
Страница 178: ...5 6 4 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 274: ...7 1 0 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 275: ...Troubleshooting 365 575 925R1 5 Lucent Technologies 8 1 Issue 1 April 2002 CHAPTER 8 Troubleshooting...
Страница 281: ...Contacting Lucent 365 575 925R1 5 Lucent Technologies 9 1 Issue 1 April 2002 CHAPTER 9 Contacting Lucent...
Страница 283: ...Appendices 365 575 925R1 5 Lucent Technologies A P 1 Issue 1 April 2002 APPENDICES...
Страница 324: ......