Detailed OptiStar EdgeSwitch CLI Reference Guide
365-575-925R1.5
Lucent Technologies
5 - 2 1
Issue 1, April 2002
5.3 Configuration Tasks
When this option is selected, the following sub menu will be displayed:
Configuration
F1 (Main Menu)
F2 or .. (Previous Menu)
F3 (Exit)
[1] BOOTP/TFTP Configuration
(For help on this item, go to
Section 5.3.1 on page 5-21
)
[2] System Information
(For help on this item, go to
Section 5.3.2 on page 5-22
)
[3] Port Parameters
(For help on this item, go to
Section 5.3.3 on page 5-24
)
[4] IP Parameters
(For help on this item, go to
Section 5.3.4 on page 5-29
)
[5] Port Mapping
(For help on this item, go to
Section 5.3.5 on page 5-31
)
[6] Routing Configuration
(For help on this item, go to
Section 5.3.6 on page 5-31
)
[7] Spanning Tree Protocol
(For help on this item, go to
Section 5.3.7 on page 5-43
)
[8] Forwarding Database Entry
(For help on this item, go to
Section 5.3.8 on page 5-45
)
[9] FCIP Network Module Configuration
(For help on this item, go to
Section 5.3.9 on page 5-46
)
Enter your Choice >
Enter a number from the Configuration menu to go to the corresponding category.
5.3.1 BOOTP/TFTP Configuration
The following 4 sections enable the user to configure the BOOTP/TFTP parameters for the OptiStar
EdgeSwitch.
5.3.1.1 Enable TFTP to Download Firmware
Menu Path:
[3] Configuration
→
[1] BOOTP/TFTP Configuration
→
[1] Enable TFTP to Download Firmware
Description:
The TFTP Server IP Address is required before beginning the download process. To verify the TFTP Server IP
Address and the Firmware File Name, from the main menu follow the path:
[1] Operational Information & Status
→
[5] BOOTP/TFTP Parameter
For help,
see Section 5.1.5
.
To enter a new TFTP Server IP Address, from the main menu follow the path:
[3] Configuration
→
[1] BOOTP/TFTP Configuration
→
[3] Set TFTP Server IP Address
For help,
see Section 5.3.1.3
.
To enter a new Firmware File Name, from the main menu follow the path:
[3] Configuration
→
[1] BOOTP/TFTP Configuration
→
[4] Set OptiStar EdgeSwitch Firmware File Name:
For help,
see Section 5.3.1.4
.
Once you have verified that the TFTP Server IP Address is entered correctly, then answer
y
(yes) or
n
(no) as to
whether you want to update the firmware through TFTP. The OptiStar EdgeSwitch will need to be rebooted for
these changes to take effect.
Содержание OptiStar EdgeSwitch
Страница 4: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 20: ...x v i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 26: ...x x i i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 27: ...Product Overview 365 575 925R1 5 Lucent Technologies 1 1 Issue 1 April 2002 CHAPTER 1 Product Overview...
Страница 62: ...3 1 2 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS LEFT INTENTIONALLY BLANK...
Страница 178: ...5 6 4 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 274: ...7 1 0 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 275: ...Troubleshooting 365 575 925R1 5 Lucent Technologies 8 1 Issue 1 April 2002 CHAPTER 8 Troubleshooting...
Страница 281: ...Contacting Lucent 365 575 925R1 5 Lucent Technologies 9 1 Issue 1 April 2002 CHAPTER 9 Contacting Lucent...
Страница 283: ...Appendices 365 575 925R1 5 Lucent Technologies A P 1 Issue 1 April 2002 APPENDICES...
Страница 324: ......