7 - 6
Lucent Technologies
365-575-925R1.5
Issue 1, April 2002
Step 3
To enter a new firmware file name, from the main menu follow the path:
[3] Configuration
→
[1] BOOTP/TFTP Configuration
→
[4] Set OptiStar EdgeSwitch Firmware File
Name:
Note
:
If applicable, preface the file name with the directory path indicating the file’s location on the
TFTP server.
For help,
see Section 5.3.1.4
.
Step 4
Once you have verified or modified the TFTP IP address and firmware file name you are ready to
download the firmware. From the main menu, follow the path:
[3] Configuration
→
[1] BOOTP/TFTP Configuration
→
[1] Enable TFTP to Download Firmware
Step 5
Type
y
(yes) to update the firmware through TFTP or
n
(no) to cancel the operation.
Once the firmware is downloaded, it is written to flash memory and from the next boot forward the most
recently downloaded firmware will be used.
7.3.2 Installing New FCIP Network Module Firmware
FCIP Network Module firmware can be uploaded via either the OptiStar EdgeSwitch 10/100BaseT network
connection or a Gigabit Ethernet network connection (applicable only if the OptiStar EdgeSwitch contains a
Gigabit Ethernet Network Module). The firmware upload process must be done independently for each FCIP
Network Module.
Note:
In order to upload new FCIP Network Module firmware, the user must be logged in to
the CLI via the serial port (
see Section 4.2.1.1.2
). This function is not available via a telnet CLI session or via
Web-based Management.
Step 1
First, determine whether you will be using the 10/100BaseT network connection or a Gigabit Ethernet
network connection to upload the firmware.
To upload FCIP Network Module firmware using the OptiStar EdgeSwitch 10/100BaseT
network connection:
a.
Ensure that the OptiStar EdgeSwitch is configured correctly and that the PC NIC card has been
configured to be on the same subnet as the OptiStar EdgeSwitch 10/100BaseT port (
see Section
4.5
).
b. Ensure that the FCIP Network Module has been configured correctly (
see Section 4.8
).
c.
Continue the upload process by going to Step (2) below.
To upload FCIP Network Module firmware using the OptiStar EdgeSwitch Gigabit Ethernet
network connection:
a.
Ensure that the OptiStar EdgeSwitch is configured correctly (
see Section 4.5
).
b. Ensure that the Gigabit Ethernet network card on the PC (TFTP server) is connected directly to a
Gigabit Ethernet Network switching port on the OptiStar EdgeSwitch.
c.
Ensure that the OptiStar EdgeSwitch Gigabit Ethernet switching port is on the same subnet as
the connected Gigabit Ethernet network card.
d. Ensure that the FCIP Network Module has been configured correctly (
see Section 4.8
).
e.
Add a static route from the OptiStar EdgeSwitch to the PC with the Gigabit Ethernet network
card (for help see the tutorial in
Section 4.6
).
f.
Add static route from PC with the Gigabit Ethernet network card to FCIP Network Module.
Содержание OptiStar EdgeSwitch
Страница 4: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 20: ...x v i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 26: ...x x i i Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 27: ...Product Overview 365 575 925R1 5 Lucent Technologies 1 1 Issue 1 April 2002 CHAPTER 1 Product Overview...
Страница 62: ...3 1 2 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS LEFT INTENTIONALLY BLANK...
Страница 178: ...5 6 4 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 274: ...7 1 0 Lucent Technologies 365 575 925R1 5 Issue 1 April 2002 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 275: ...Troubleshooting 365 575 925R1 5 Lucent Technologies 8 1 Issue 1 April 2002 CHAPTER 8 Troubleshooting...
Страница 281: ...Contacting Lucent 365 575 925R1 5 Lucent Technologies 9 1 Issue 1 April 2002 CHAPTER 9 Contacting Lucent...
Страница 283: ...Appendices 365 575 925R1 5 Lucent Technologies A P 1 Issue 1 April 2002 APPENDICES...
Страница 324: ......