20 Technical data
310
20.3
Analog outputs of base unit and optional boards
20.4
Binary inputs base unit
20.5
Binary inputs optional boards
20.6
Binary outputs, power supply unit board
Signal type
Signal range
Admissible
load resistance
Accuracy
Effect of am-
bient tem-
perature
Voltage signal
0 to 10 V
> 500
Ω
≤
0.25 %
≤
100 ppm / K
Current signal
0/4 to 20 mA
< 450
Ω
≤
0.25 %
≤
100 ppm / K
Description
Input frequency
ranges
Min. pulse dura-
tion
Signal type
Switching thresh-
olds
a
a
This specification is relevant only if the Ext. voltage supply is selected under the “Contact” point in the
Configuration. Sensors and transmitters should be supplied from voltage supply outputs on the JUMO
AQUIS touch P. An externally supplied voltage signal must not have a voltage over 28 V.
On Off
On
Off
IN 1
b
b
All digital inputs IN 1 to 3 are suitable for connecting proximity switches. Recommended
types are: Wachendorff P2C2B1208NO3A2 and Balluff BES M12EG-PSC80F-BP03.
≤
1 Hz
300 ms
300 ms
Configurable as:
potential-free con-
tact,
or
ext. voltage supply
(maximal 28 V)
> 8 V
> 1.8 mA
< 5 V
< 1.2 mA
IN 2 to 3
b,c
Switching sig-
nal
c
Digital inputs IN 2 and IN 3 can be used for impeller flow-through sensors (water meters) or
magnetic-inductive flow-through meters (square-wave signal), for example. The input frequency depends
on the configured measuring principle in the flow-through function.
≤
1 Hz
30
μ
s
30
μ
s
IN 2 to 3
b,c
Flow
3 to 300 Hz
300 Hz
to
10 kHz
30
μ
s
30
μ
s
Max. number of retrofittable
digital inputs
Max.
pulse frequen-
cy
Min. pulse dura-
tion
Signal type
On Off
max. 2 optional boards with 3 digi-
tal inputs each
1 Hz
300 ms
300 ms
Potential-free contact
Description
Switching out-
put
Ampacity at ohm-
ic load
Contact life
a
a
The maximal ampacity of the contacts must not be exceeded.
OUT 1
Relay, change-
over contact
3 A at AC 250 V
150,000 switching cy-
cles
OUT 2
Relay, change-
over contact
Содержание AQUIS touch P 202580
Страница 12: ...Content...
Страница 26: ...4 Identifying the device version 26...
Страница 29: ...29 5 Mounting Mounting depth with Ci conductivity sensor 283 3 mm 2 3 mm 36 mm 25 mm 23 2 mm...
Страница 32: ...5 Mounting 32...
Страница 64: ...7 Startup 64...
Страница 100: ...1 2 3 4 5...
Страница 107: ...107 8 Operation Example of a Quad View...
Страница 108: ...8 Operation 108...
Страница 114: ...9 Parameterization 114...
Страница 160: ...10 Configuration 160...
Страница 182: ...13 Calibrating a pH measuring chain 182...
Страница 196: ...16 Calibrating CR conductivity sensors 196...
Страница 206: ...17 Calibrating Ci conductivity sensors 206...
Страница 214: ...18 Calibrating universal inputs 214...
Страница 228: ...19 PC Setup Program 228...
Страница 319: ...319 20 Technical data...
Страница 320: ...20 Technical data 320...
Страница 321: ......