![JUMO AQUIS touch P 202580 Скачать руководство пользователя страница 302](http://html1.mh-extra.com/html/jumo/aquis-touch-p-202580/aquis-touch-p-202580_operating-manual_2031168302.webp)
19 PC Setup Program
302
Battery
The
voltage of the backup battery
and the
circuit board temperature
in the
device are displayed in the JUMO PC setup program.
Open:
Online Parameters
r
Adjusting / Testing (double-click)
r
Battery tab
Touch
In this view, touchscreen calibration (see "Calibrating the touchscreen", page
84) can be started from the JUMO PC setup program. In addition, the calibration
data for the touchscreen are displayed in detail. These are used to diagnose
problems with touch operation together with JUMO Service.
Open:
Online Parameters
r
Adjusting / Testing (double-click)
r
Touch tab
Display
Four different test images can be activated on the device display on this tab.
These are used to diagnose display problems together with JUMO Service.
Open:
Online Parameters
r
Adjusting / Testing (double-click)
r
Display tab
Various process values
Process data are selected here for display in the online window.
In addition to tabs with standard selections of process data, the online window
contains the "Selected Process Data" tab. The process data selected here are
displayed on this tab.
CAUTION!
A buffer battery is built into the device. Its purpose is to maintain data when the
device is switched off or if the voltage supply is interrupted. If the battery ap-
proaches the end of its operating life (approximately 7 years) then a battery
prealarm will indicate that status. When the battery is empty a battery alarm will
indicate that status. The battery must be exchanged before it is empty. The bat-
tery must be exchanged by the JUMO Service department! In this case, send
in the device!
NOTE!
Process data from the internal device memory can be displayed in real time in
the online window.
v
Chapter "Online data", Page 226
A requirement for real-time display of process data is an existing connection
between the JUMO PC setup program and the device.
Содержание AQUIS touch P 202580
Страница 12: ...Content...
Страница 26: ...4 Identifying the device version 26...
Страница 29: ...29 5 Mounting Mounting depth with Ci conductivity sensor 283 3 mm 2 3 mm 36 mm 25 mm 23 2 mm...
Страница 32: ...5 Mounting 32...
Страница 64: ...7 Startup 64...
Страница 100: ...1 2 3 4 5...
Страница 107: ...107 8 Operation Example of a Quad View...
Страница 108: ...8 Operation 108...
Страница 114: ...9 Parameterization 114...
Страница 160: ...10 Configuration 160...
Страница 182: ...13 Calibrating a pH measuring chain 182...
Страница 196: ...16 Calibrating CR conductivity sensors 196...
Страница 206: ...17 Calibrating Ci conductivity sensors 206...
Страница 214: ...18 Calibrating universal inputs 214...
Страница 228: ...19 PC Setup Program 228...
Страница 319: ...319 20 Technical data...
Страница 320: ...20 Technical data 320...
Страница 321: ......