P2.047
Auto resonance suppression mode
Address: 025EH
025FH
Default:
0x0001
Control mode: All
Unit:
-
Setting range: 0x0000 - 0x01F2
Format:
HEX
Data size:
16-bit
Settings:
Y
Z
U
X
X
Auto resonance suppression function
Z
Fixed resonance suppression parameter
Y
Fixed resonance suppression parameter
U
Reserved
X: auto resonance suppression function
0: disable auto resonance suppression. After the function is disabled, the existing resonance
suppression parameter values do not change.
1: auto resonance suppression mode 1; when the servo determines it is stable*
2
, the servo stores
the resonance suppression points in EEPROM (non-volatile memory for parameters), and
disables the auto resonance suppression function (X = 0). Before the servo is stable,
(1)
If you cycle power on the servo drive, the found resonance suppression points are lost and
will not be saved. The servo searches for the resonance suppression points again.
(2)
If you switch the setting of X from 1 to 0, the known resonance suppression points will be
stored in EEPROM.
(3)
If you keep the setting of X as 1, the known resonance suppression points will not be
cleared, but they are not written to EEPROM yet. They are written to EEPROM when the
servo determines it is stable.
2: auto resonance suppression mode 2; when the servo determines it is stable*
2
, the servo stores
the resonance suppression points in EEPROM (non-volatile memory for parameters). In this
mode, the searching cycle continues until the 5 sets of resonance suppression parameters are
set, then the auto resonance suppression function is disabled (X = 0). Before the servo is stable,
(1)
If you cycle power on the servo drive, the resonance suppression points that are not yet
stored in EEPROM are lost and will not be saved. The resonance suppression points that
are stored in EEPROM will not be affected.
(2)
If you switch the setting of X from 2 to 0, the known resonance suppression points will be
stored in EEPROM.
(3)
If you keep the setting of X as 2, the known resonance suppression points will not be
cleared, but they are not written to EEPROM yet. They are written to EEPROM when the
servo determines it is stable.
Содержание ASDA-A3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Страница 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Страница 296: ...ASDA A3 Motion Control 7 99 7 Figure 7 3 4 6 ASDA Soft Speed fitting setting interface for creating E Cam table ...
Страница 320: ...ASDA A3 Motion Control 7 123 7 Figure 7 3 7 14 ASDA Soft rotary shear intermittent printing machine setting interface ...
Страница 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Страница 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Страница 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Страница 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Страница 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Страница 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Страница 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Страница 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...