ASDA-A3 Parameters
8-7
8
Position control parameters - internal register control command (PR mode)
Parameter
No.
Function
Default value
Unit
Control mode
PT PR S T
P5.008
Forward software limit
2147483647
PUU
-
O -
-
P5.009
Reverse software limit
-
2147483648
PUU
-
O -
-
P6.002 -
P7.099
Internal Position commands 1 - 99
0
-
-
O -
-
P5.060 -
P5.075
Internal Position commands control the
movement speeds from 0 - 15
20 - 3000
(panel / software)
1 rpm (rotary)
10
-
6
m/s (linear)
(panel /
software)
-
O -
-
200 - 30000
(communication)
0.1 rpm (rotary)
10
-
6
m/s (linear)
(communication)
P5.004
Homing methods
0x0000
-
-
O -
-
P5.005
High speed homing (first speed setting)
100
(panel / software)
1 rpm (rotary)
10
-
6
m/s (linear)
(panel /
software)
-
O -
-
1000
(communication)
0.1 rpm (rotary)
10
-
6
m/s (linear)
(communication)
-
O -
-
P5.006
Low speed homing (second speed
setting)
20
(panel / software)
1 rpm (rotary)
10
-
6
m/s (linear)
(panel /
software)
-
O -
-
200
(communication)
0.1 rpm (rotary)
10
-
6
m/s (linear)
(communication)
-
O -
-
P5.007■
Trigger Position command
(PR mode only)
0
-
-
O -
-
P5.040 -
P5.055
Delay times after position reached
0 - 5500
ms
-
O -
-
P5.098
PR# triggered by event rising-edge
0x0000
-
-
O -
-
P5.099
PR# triggered by event falling-edge
0x0000
-
-
O -
-
P5.015■
PATH#1 - PATH#2 volatile setting
0x0000
-
-
O -
-
(
★
) Read-only parameter. Can only read the value of the parameter. For example, P0.000, P0.010, P4.000, etc.
(▲) Parameter cannot be changed when servo is in Servo On status. For example, P1.000 and P1.046.
( ● ) Parameter changes become valid after cycling the power. For example, P1.001 and P3.000.
( ■ ) Parameter resets to its default value after cycling the power. For example, P3.006.
Содержание ASDA-A3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Страница 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Страница 296: ...ASDA A3 Motion Control 7 99 7 Figure 7 3 4 6 ASDA Soft Speed fitting setting interface for creating E Cam table ...
Страница 320: ...ASDA A3 Motion Control 7 123 7 Figure 7 3 7 14 ASDA Soft rotary shear intermittent printing machine setting interface ...
Страница 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Страница 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Страница 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Страница 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Страница 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Страница 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Страница 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Страница 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...