![Delta ASDA-A3 Series Скачать руководство пользователя страница 760](http://html1.mh-extra.com/html/delta/asda-a3-series/asda-a3-series_user-manual_2474523760.webp)
ASDA-A3 Troubleshooting
13-15
13
AL019 Serial communication error
Trigger condition
and cause
Condition: RS-485 communication error.
Cause:
1.
Improper setting of the communication parameters.
2.
Incorrect communication address.
3.
Incorrect communication value.
Checking method
and corrective action
1.
Check the values of the communication parameters. Then correctly set P3.003
and P3.004 or restore the value to default.
2.
Check and correctly set the communication address.
3.
Check and correctly set the accessing value.
How to clear the
alarm?
DI.ARST
AL020 Serial communication timeout
Trigger condition
and cause
Condition: RS-485 communication error.
Cause:
1.
Improper setting of the timeout parameter (P5.003).
2.
Servo drive has not received the communication command for a long time and
has timed out (refer to P5.003).
Checking method
and corrective action
1.
Check and make sure the value for the communication timeout parameter is
correct.
2.
Check if the communication cable is loose or broken and is correctly wired.
How to clear the
alarm?
DI.ARST
AL022 RST leak phase
Trigger condition
and cause
Condition: RST power cable is loose or there is no power. The default setting of
AL022 is a warning. To set AL022 as an alarm, you can set P2.066 [Bit 12].
Cause: RST leak phase.
Checking method
and corrective action
Check if the RST power cable is loose or there is no power. This alarm occurs when
the 1.5 kW (or below) ASDA-A3 servo drive is not connected to the three-phase
power supply. For 2 kW (or above) ASDA-A3 servo drives, the alarm occurs when
one single phase is not connected to the power supply. Correctly connect the power
to the servo drive. If the issue persists, send your ASDA-A3 servo drive back to the
distributor or contact Delta.
How to clear the
alarm?
DI.ARST
Содержание ASDA-A3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Страница 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Страница 296: ...ASDA A3 Motion Control 7 99 7 Figure 7 3 4 6 ASDA Soft Speed fitting setting interface for creating E Cam table ...
Страница 320: ...ASDA A3 Motion Control 7 123 7 Figure 7 3 7 14 ASDA Soft rotary shear intermittent printing machine setting interface ...
Страница 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Страница 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Страница 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Страница 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Страница 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Страница 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Страница 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Страница 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...