![Delta ASDA-A3 Series Скачать руководство пользователя страница 589](http://html1.mh-extra.com/html/delta/asda-a3-series/asda-a3-series_user-manual_2474523589.webp)
Parameters ASDA-A3
8-216
8
Value: 0x11, 0x12, 0x13, 0x1A, 0x1B, 0x1C, 0x1E
DI name
Description
Triggering
method
Control
mode
POS0
POS1
POS2
POS3
POS4
POS5
POS6
PR command selection (1 - 99)
Position
command
POS
POS
POS
POS
POS
POS
POS
CTRG
Corres-
ponding
para-
meter
6
5
4
3
2
1
0
Homing
0
0
0
0
0
0
0
P6.000
P6.001
PR 1
0
0
0
0
0
0
1
P6.002
P6.003
~
PR 50
0
1
1
0
0
1
0
P6.098
P6.099
PR 51
0
1
1
0
0
1
1
P7.000
P7.001
~
PR 99
1
1
0
0
0
1
1
P7.098
P7.099
Level
triggered
PR
Value: 0x1D
DI name
Description
Triggering
method
Control
mode
ABSE
When DI.ABSE is on, it is in absolute mode and can enable the functions
of DI.ABSQ, DI.ABSC, DI.ABSR, DI.ABSD, and DI.ABSC at the same
time.
When DI.ABSE is on, the functions of DI4, DO2, and DO3 are no longer
the ones assigned by the parameter. The DI4 function will be DI.ASDQ,
DO2 will be DI.ABSR, and DO3 will be DI.ABSD. In addition, DI pins of
DI.ABSC can be assigned by parameters.
Level
triggered
All
Value: 0x1F
DI name
Description
Triggering
method
Control
mode
ABSC
When DI.ABSC is on, the number of turns stored in absolute encoder are
cleared. But this DI is only valid when DI.ABSE is on.
Rising-edge
triggered
All
Value: when DI.ABSE is on, the DI.ABSQ from DI4 replaces the DI4 function from P2.013
DI name
Description
Triggering
method
Control
mode
ABSQ
always
input by
DI4
During I/O transmission, the controller sends the handshaking signal.
When DI.ABSQ is off, the controller issues the request; when DI.ABSQ
is on, the controller has processed the ABSD signal. This DI is only valid
when DI.ABSE is on. Refer to Figure 10.3.4. for a detailed description.
Rising- and
falling-edge
triggered
All
Содержание ASDA-A3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Страница 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Страница 296: ...ASDA A3 Motion Control 7 99 7 Figure 7 3 4 6 ASDA Soft Speed fitting setting interface for creating E Cam table ...
Страница 320: ...ASDA A3 Motion Control 7 123 7 Figure 7 3 7 14 ASDA Soft rotary shear intermittent printing machine setting interface ...
Страница 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Страница 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Страница 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Страница 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Страница 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Страница 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Страница 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Страница 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...