Installation ASDA-A3
2-14
2
Installation precautions
The ferrite ring is commonly used when peripheral devices (such as the controller) are affected
by noise from conduction and radiation when the servo motor is in the Servo On state. The
parasitic capacitance between the cables in the wiring panel and the ground is typically small,
but as the frequency of the signal increases (Servo On state), the resistance of the parasitic
capacitance becomes small enough for the common-mode current to flow through. Normally,
common-mode current only leads to common-mode interference due to an unstable circuit
caused by a poor connection between the power circuit and ground. If the common-mode current
flows through the external cables, common-mode interference may also happen due to electrical
interference caused by unstable electric potential.
The ferrite ring causes eddy current losses to high-frequency signals and transforms them into
heat when suppressing common-mode interference. The ferrite ring acts as a low-pass filter to
effectively suppress high-frequency noise and ensure the stability of the circuit while the
impedance to low-frequency signals is relatively small.
Winding several turns of wire onto the ferrite ring can increase inductance and the ability to filter
out high-frequency noise. The suggested winding methods are shown below.
1.
For A3-220V model (4.5 kW - 7.5 kW)
2.
For A3-220V model (11 kW - 15 kW)
Note:
1.
Refer to Section 3.1.4 for the selection of the motor power cable.
2.
Only the motor power cable or power cable can run through the ferrite ring. If needed, prepare extra
ferrite rings for grounding.
3.
An EMI filter may be required for absorbing radiation when using a longer motor power cable.
Содержание ASDA-A3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Страница 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Страница 296: ...ASDA A3 Motion Control 7 99 7 Figure 7 3 4 6 ASDA Soft Speed fitting setting interface for creating E Cam table ...
Страница 320: ...ASDA A3 Motion Control 7 123 7 Figure 7 3 7 14 ASDA Soft rotary shear intermittent printing machine setting interface ...
Страница 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Страница 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Страница 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Страница 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Страница 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Страница 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Страница 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Страница 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...