Troubleshooting ASDA-A3
13-18
13
AL028 Encoder voltage error or encoder internal error
Trigger condition
and cause
Condition: servo drive charging circuit is not removed so the battery voltage is higher
than the specification (> 3.8V) or the encoder signal is in error.
Cause:
1.
Voltage level of the battery is too high.
2.
Encoder internal error.
Checking method
and corrective
action
1.
Follow the testing procedure for overvoltage / overcurrent and troubleshoot.
This automatically clears AL028.
(a)
Check the servo drive charging circuit. Avoid incorrect wiring. If Pin 1
(5V) of CN2 is connected to BAT+, it means the power (5V) of the servo
drive is being charged to the battery.
(b)
Check if the battery is correctly installed (voltage > 3.8V).
2.
(a) Make sure the encoder is the absolute type. Check and remove the
cause for the alarm. If the issue persists, send your servo drive back to
the distributor or contact Delta.
(b)
Make sure the servo motor is properly grounded and connect the
ground of the UVW connector (green) to the servo drive heat sink.
(c)
Make sure the encoder signal cable is separated from the power supply
or any high-current cables to avoid interference.
(d)
Use shielded cable for the encoder. If the issue persists, send your
servo drive back to the distributor or contact Delta.
How to clear the
alarm?
Cycle power on the servo drive.
AL029 Gray code error
Trigger condition
and cause
Absolute position error
Checking method
and corrective
action
Cycle the power to the servo drive to operate the motor. Then, check if the alarm
occurs again.
If the issue persists, replace the encoder.
How to clear the
alarm?
Cycle power on the servo drive.
Содержание ASDA-A3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Страница 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Страница 296: ...ASDA A3 Motion Control 7 99 7 Figure 7 3 4 6 ASDA Soft Speed fitting setting interface for creating E Cam table ...
Страница 320: ...ASDA A3 Motion Control 7 123 7 Figure 7 3 7 14 ASDA Soft rotary shear intermittent printing machine setting interface ...
Страница 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Страница 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Страница 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Страница 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Страница 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Страница 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Страница 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Страница 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...