ASDA-A3 Troubleshooting
13-33
13
AL085 Regeneration error
Trigger condition
and cause
Condition: regeneration control error.
Cause: regenerative resistor is not operating, but the regenerative voltage remains
at 400V for a period of time.
Checking method
and corrective action
Check the connections for the regenerative resistor, re-calculate the value for the
regenerative resistor, and reset the values of P1.052 and P1.053. If this does not
clear the alarm, send your servo drive back to Delta.
How to clear the
alarm?
DI.ARST
AL086 Input voltage is too high
Trigger condition
and cause
Condition: when the servo drive detects no regenerative power, but other
regenerative energy (such as interference) is input to the servo drive, or the input
voltage is higher than the permissible rated voltage.
Cause:
1.
Other energy (such as interference) is input to the servo drive or the input
voltage is higher than the permissible rated voltage.
2.
Malfunction of the servo drive hardware.
Checking method
and corrective action
1.
Use a voltmeter to measure if the input voltage from the power source is
within the permissible rated voltage (see the servo drive specifications).
If the voltage exceeds the rated value, remove the interference source. If you
cannot eliminate the interference, the interference can be consumed with an
external resistor by setting P2.065 bit3 to 0 and P2.094 bit4 to 0.
2.
If the voltmeter detects that the voltage input from the main circuit is within the
permissible rated voltage but the issue persists, then the servo drive may be
malfunctioning.
How to clear the
alarm?
1.
Use the correct voltage source or connect the voltage regulator in series.
2.
Send your servo drive back to the distributor or contact Delta.
AL088 Servo function overload warning
Trigger condition
and cause
Condition: too many motor control functions on the servo drive are enabled.
Cause: servo function overload warning.
Checking method
and corrective action
If using a filter, see if using this filter is necessary.
How to clear the
alarm?
Disable the filter if it is not required, such as the low-pass filter (P1.006 - P1.008),
moving filter (P1.068), low-frequency vibration suppression (P1.025 - P1.028),
vibration elimination (P1.089 - P1.094), or Notch filter (1
st
to 5
th
sets).
Содержание ASDA-A3 Series
Страница 15: ... This page is intentionally left blank ...
Страница 89: ...Wiring ASDA A3 3 38 3 Pin assignment for the CN1 quick connector J2 and J1 ...
Страница 91: ...Wiring ASDA A3 3 40 3 Wiring for CN1 quick connector and installation Installation ...
Страница 296: ...ASDA A3 Motion Control 7 99 7 Figure 7 3 4 6 ASDA Soft Speed fitting setting interface for creating E Cam table ...
Страница 320: ...ASDA A3 Motion Control 7 123 7 Figure 7 3 7 14 ASDA Soft rotary shear intermittent printing machine setting interface ...
Страница 373: ...Motion Control ASDA A3 7 176 7 This page is intentionally left blank ...
Страница 605: ...Parameters ASDA A3 8 232 8 This page is intentionally left blank ...
Страница 623: ...MODBUS Communication ASDA A3 9 18 9 This page is intentionally left blank ...
Страница 645: ...Absolute System ASDA A3 10 22 10 This page is intentionally left blank ...
Страница 661: ...Linear Motor ASDA A3 11 16 11 This page is intentionally left blank ...
Страница 793: ...Troubleshooting ASDA A3 13 48 13 This page is intentionally left blank ...
Страница 819: ...Specifications ASDA A3 A 26 A This page is intentionally left blank ...
Страница 841: ...Accessories ASDA A3 B 22 B This page is intentionally left blank ...