General Settings
The following general parameters are used for configuration of each server:
•
Name
The name given to the server object for reference purposes in NetDefendOS. For example,
NetDefendOS authentication rules may be defined which reference this name.
This value has nothing to do with the
Name Attribute
described below. It is only for use by
NetDefendOS and not the LDAP server.
•
IP Address
The IP address of the LDAP server.
•
Port
The port number on the LDAP server which will receive the client request which is sent using
TCP/IP.
The default port number is
389
.
•
Source IP Selection
By default (
Automatic
), the IP address of the firewall's sending interface will be used as the
source address for traffic sent to the LDAP server. If this property is set to
Manual
, a specific
source IP address can be specified.
If a specific source IP address is specified, the administrator must also manually configure
NetDefendOS to ARP publish the IP address on the sending interface. Doing this is described
in
The default value is
Automatic
.
•
Timeout
This is the timeout length for LDAP server user authentication attempts in seconds. If no
response to a request is received from the server after this time then the server will be
considered to be unreachable.
The default timeout setting is
5
seconds.
•
Name Attribute
The
Name Attribute
is the ID of the data field on the LDAP server that contains the username.
The NetDefendOS default value for this is
uid
which is correct for most UNIX based servers.
If using Microsoft Active Directory this should be set to
SAMAccountName
(which is NOT case
sensitive). When looking at the details of a user in Active Directory, the value for the user
login name is defined in the
SAMAccountName
field under the
Account
tab.
Note: The LDAP server database determines the correct value
This is an attribute tuple and the LDAP server's database schema definitions
Chapter 8: User Authentication
618
Содержание NetDefendOS
Страница 30: ...Figure 1 3 Packet Flow Schematic Part III Chapter 1 NetDefendOS Overview 30 ...
Страница 32: ...Chapter 1 NetDefendOS Overview 32 ...
Страница 144: ...Chapter 2 Management and Maintenance 144 ...
Страница 220: ... Enable DHCP passthrough Enable L2 passthrough for non IP protocols 4 Click OK Chapter 3 Fundamentals 220 ...
Страница 267: ... SourceNetwork lannet DestinationInterface any DestinationNetwork all nets 4 Click OK Chapter 3 Fundamentals 267 ...
Страница 284: ...Chapter 3 Fundamentals 284 ...
Страница 360: ...The ospf command options are fully described in the separate NetDefendOS CLI Reference Guide Chapter 4 Routing 360 ...
Страница 392: ...Chapter 4 Routing 392 ...
Страница 396: ...Web Interface 1 Go to Network Ethernet If1 2 Select Enable DHCP 3 Click OK Chapter 5 DHCP Services 396 ...
Страница 419: ... Host 2001 DB8 1 MAC 00 90 12 13 14 15 5 Click OK Chapter 5 DHCP Services 419 ...
Страница 420: ...Chapter 5 DHCP Services 420 ...
Страница 424: ...2 Now enter Name lan_Access Action Expect Interface lan Network lannet 3 Click OK Chapter 6 Security Mechanisms 424 ...
Страница 573: ...Chapter 6 Security Mechanisms 573 ...
Страница 575: ...This section describes and provides examples of configuring NAT and SAT rules Chapter 7 Address Translation 575 ...
Страница 607: ...Chapter 7 Address Translation 607 ...
Страница 666: ...Chapter 8 User Authentication 666 ...
Страница 775: ...Chapter 9 VPN 775 ...
Страница 819: ...Chapter 10 Traffic Management 819 ...
Страница 842: ...Chapter 11 High Availability 842 ...
Страница 866: ...Default Enabled Chapter 13 Advanced Settings 866 ...
Страница 879: ...Chapter 13 Advanced Settings 879 ...