Section 06 ELECTRICAL SYSTEM
Subsection 04 (LIGHTS, GAUGE AND ACCESSORIES)
vmr2007-043-010_a
Use the Fluke 115 multimeter (P/N 529 035 868)
and set it to the diode symbol as shown.
vmr2006-020-005
Probe wires while paying attention to the diode
polarity.
WIRES TO PROBE (HARNESS SIDE)
DIODE
WINCH SWITCH
CONNECTOR
WINCH RELAY
POST
D5
GREEN/BLUE
D6
BLUE/GREEN
Ground
Probe diodes in both forward and backwards po-
larity for proper testing. See illustrations.
vmr2007-043-011_b
REVERSE POLARITY (MUST BE OPEN CIRCUIT)
vmr2007-043-011_a
FORWARD POLARITY (MUST BE AROUND 0.5 V)
If a diode fails the test, replace the diode.
NOTE:
Diodes are located in wiring harness ap-
proximately where shown in following illustration.
vmr2008-140