Section 06 ELECTRICAL SYSTEM
Subsection 03 (STARTING SYSTEM)
vmr2006-020-005
Probe wires while paying attention to the diode
polarity.
vmr2008-139-005_c
FORWARD POLARITY, MUST BE AROUND 0.5 V
vmr2008-139-005_d
REVERSE POLARITY, MUST BE OPEN CIRCUIT
If test failed, replace diode.
NOTE:
Diode is located in main wiring harness
near solenoid. It is approximately 22 cm (8-3/4 in)
from the main fuse holder as shown in following
picture.
vmr2008-139-018_a
1. D4 diode location
2. Starter solenoid
Solenoid Continuity Test
Disconnect the black (-) negative battery cable.
Disconnect the small terminal wires from the so-
lenoid.
vmr2008-139-005_a
1. Small solenoid coil wires
2. Small solenoid coil terminals
Set Fluke 111 multimeter (P/N 529 035 868) to
.
Measure solenoid coil resistance as follows.
MEASUREMENT
SOLENOID TERMINALS
RESISTANCE
@ 20°C (68°F)
A
B
Approx. 6
282
vmr2008-139