Section 06 ELECTRICAL SYSTEM
Subsection 02 (CHARGING SYSTEM)
When using a constant current charger, charge
battery according to the chart below.
Battery Voltage Below 12.8 V and Above 11.5 V
STANDARD CHARGING
(RECOMMENDED)
BATTERY
TYPE
TIME
CHARGE
YTX20L-BS
4 - 9 hours
2 A
QUICK CHARGING
BATTERY
TYPE
TIME
CHARGE
YTX20L-BS
50 minutes
10 A
Battery Installation
WARNING
Always connect RED (+) cable first then
BLACK (-) cable.
Install the battery insulator pad on the battery.
Insert the fasteners in the battery posts.
Place battery on a support behind vehicle with the
positive terminal to the left.
Route the RED (+) battery cable over and in line
with the battery lengthwise.
Connect the RED battery cable to the positive (+)
battery post.
Apply silicone dielectric grease (P/N 293 550 004)
on battery posts and connections.
Install the red rubber boot over the battery post.
vmr2008-138-009_b
BATTERY TERMINALS FACING VEHICLE
1. Connect RED (+) battery cable
2. Install red rubber boot over battery post
With the left hand, lift the BLACK battery cable
and holding strap as you insert the battery in the
battery support.
Properly position battery with the positive post to-
wards the front and the negative post towards the
rear.
vbl2008-005-502_a
BATTERY CABLE ROUTING
Secure with battery holding strap.
Connect the BLACK (-) battery cable.
vmr2008-138-008_a
1. Secure with battery holding strap
2. Connect the BLACK (-) battery cable
ELECTRICAL SYSTEM MAIN
GROUND
Remove starter solenoid cover.