Add IP Solutions
Issue 7 November 2003
7-77
555-233-115
Figure 7-14.
External Modem Connections for U.S. Robotics Sportster
Figure Notes
1. Connect analog line here.
2. DIP switch 5 must be up.
3. Connect MODEM connector here.
4. Connect power connector here.
Table 7-14.
U.S. Robotics Modem DIP Switch Settings
DIP Switch
Setting
Description
1
UP
DOWN
Data Terminal Ready normal
Data Terminal Ready override
2
UP
DOWN
Verbal result codes
Numeric result codes
3
UP
DOWN
Suppress result codes
Display result codes
4
UP
DOWN
Echo offline commands
No echo, offline commands
5
UP
DOWN
Auto answer on first ring or higher if specified in NVRAM
Auto answer off
6
UP
DOWN
Carrier detect normal
Carrier detect override
7
UP
DOWN
Load NVRAM defaults
Load factory defaults
8
UP
DOWN
Dumb mode
Smart mode
1 2 3 4 5 6 7 8
modfrobo KLC 030499
2
3
4