Upgrading R5si/R6si to an Avaya DEFINITY Server R
EPN running Avaya Communication Manager
555-233-115
4-30
Issue 7 November 2003
Administer No-License/Emergency Numbers
1. At the SAT type change system-parameters features and press
RETURN
.
The Feature-Related System Parameters screen displays.
2. In the
Emergency Numbers - Internal
field (optional) type a valid
extension.
NOTE:
This number cannot be a hunt group or ACD number.
3. In the
Emergency Number - External
field (required) type a 21-digit,
dialpad-valid character string that can include trunk access codes. The
default for this field is 911.
4. In the
No-License Incoming Call Number
field (optional) type a valid
extension.
NOTE:
This number cannot be a hunt group or ACD number.
5. Press
ENTER
to save the changes.
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select Maintenance > Reset System >
Restart System.
Label Main Distribution Frame
1. Label the MDF with the new PN number of the new EPN. The STS
software upgrade assigns the next PN number, after the highest numbered
PN in the Release 5/6si system, to the upgraded EPN.
Reconnect Cables
1. Behind each EPN cabinet power supply, set the circuit breaker to OFF.
NOTE:
Powering down an EPN cabinet without powering down the PPN will
set off alarms. However, these alarms should clear after power is
restored to the EPN.
2. Replace all cables that were labeled and removed.