Upgrading G3rV4 and R5/6/7/8r to Avaya DEFINITY
Server R running Avaya Communication Manager
555-233-115
2-36
Issue 7 November 2003
Set Tone-Clock in SPE A to Active
(High/Critical reliability only)
1. Type set tone-clock 1a and press
Enter
to move the tone clock from SPE B
to SPE A.
NOTE:
This takes 1 minute to complete. If the service state is incorrect,
repeat the command until this condition is met.
2. Type status port-network 1 and press
Enter
to verify that the Tone-Clock
has moved to SPE A. Make sure the YELLOW LED on the tone clock is
flashing.
If the Tone-Clock has not migrated to the carrier A after 1 minute, then a
Tone-Clock problem exists. Refer to the TDM-CLK maintenance object to
resolve any problems.
Lock Switches to SPE A (High/Critical
reliability only—affects service)
!
CAUTION:
THIS AFFECTS SERVICE. SPE A resets (cold 1 restart—reset system 3),
which takes about 2 minutes.
1. Lock the SPE switches one at a time on the DUPINT circuit packs to the
left (SPE A), the carrier with the 4 memory boards. This is a hard switch.
2. Wait until the login prompt appears, then log in.
3. Type status spe and press
Enter
to verify that SPE A is functional.
NOTE:
SPE A is now up and providing service. If there is a major problem that
affects service, refer to
Power Down SPE B (High/Critical
reliability only)
!
CAUTION:
Do not power down the whole cabinet; it is not necessary.
NOTE:
If there are two power supplies, power down the SPE by removing the
power plug on the left side of the carrier then by removing the power plug on
the right side of the carrier. If there is only one power supply, remove the one
power plug on the right side.
1. Power down the SPE B, the standby carrier.