Upgrading Release 9/10r to Avaya DEFINITY Server R
Running Avaya Communication Manager
555-233-115
1-16
Issue 7 November 2003
Change Vector Directory Number administration
If the
Message Server Name
field on page 2 of the Vector Directory Number
form is
msa
, remove this administration (
Screen 1-11.
Vector Directory Number form
Duplicate System Software
In case the upgrade fails for any reason:
1. Ensure that the customer’s previous systems software is on site.
Verify System Status
1. Type display alarms and press
RETURN
.
2. If there are alarms, take the necessary corrective actions.
3. Type display errors and press
RETURN
.
4. Examine the error log and record any Error Code 18 alarm that identifies
existing busyouts. After the upgrade you will restore the busyouts as they
were.
5. Execute the following commands to see whether the switch has
administration:
— list station
— list trunk-group
— list hunt-group
— list data-module
— list announcements
If any command does not complete successfully, escalate the problem
immediately. After the upgrade you will check the same administration to ensure
that the translations are intact.
change vdn 5000
Page 2 of 2
VECTOR DIRECTORY NUMBER
AUDIX Name:
Messaging Server Name:
Return Destination:
VDN Timed ACW Interval:
BSR Application:
BSR Available Agent Strategy: 1st-found