Upgrading G3rV4 and R5/6/7/8r to Avaya DEFINITY
Server R running Avaya Communication Manager
555-233-115
2-20
Issue 7 November 2003
Check link status
1. Enter display communication-interface links and press
RETURN
.
2. Note all administered links.
3. Type
status link
number
and press
RETURN
for each administered link.
Check the following fields for the values listed:
■
Link Status
= connected
■
Service State
= in service
NOTE:
For Release 7 and later, the only way to determine if an ISDN-PRI
D-Channel is up is to
1. Type list signaling group and press
RETURN
.
Note the signaling groups listed by number.
2. For each of the signaling groups listed, type status signaling
group <number> and press
RETURN
.
4. If any of the links are not up, take the necessary corrective action to restore
the link before continuing with the upgrade.
Check Clock Synchronization
1. Type status sync and press
Enter
to verify that the clock synchronization is
good. If not, contact the network to resolve.
Check for Translation Corruption
1. Type newterm and press
Enter
. If you do not get a login prompt and see the
following message:
Warning: Translation corruption detected
follow the normal escalation procedure for translation corruption before continuing
the upgrade.
2. If R5r or earlier, execute the following commands and note the status:
■
list trunk-group
■
list hunt-group
■
list data-module
■
list integrated announcements (if any)