Task Table
Issue 7 November 2003
1-25
555-233-115
Check for Translation Corruption
1. Type newterm and press
RETURN
.
2. If you do not get a login prompt and see the following message:
Warning: Translation corruption detected
follow the normal escalation procedure for translation corruption before
continuing the upgrade.
Verify the Upgrade
1. Type status system 1 and verify that the system is in a normal state.
Check these fields for the corresponding values:
■
Maj/Min alarms =
0
■
Service State =
in service
2. Type display alarms and press
RETURN
.
If there are alarms, take the necessary corrective actions.
3. Type list configuration software-version and press
RETURN
.
In the SOFTWARE VERSION section verify that the
Memory Resident
field matches the new software version.
4. Type display communication-links and press
RETURN
.
Ensure that the link administration is the same as before the upgrade.
5. Type status link number and press
RETURN
for each administered link.
Check these fields for the corresponding values:
■
Link Status
= connected
■
Service State
= in service
If any of the links are not up, take the necessary corrective action to restore
the link
6. Type list signaling-group press
RETURN
.
Check the system to ensure that the signaling group administration is the
same as before the upgrade.
7. For each signaling group, type status signal number and press
RETURN
.
Ensure that the
Group State
field is in-service.
If the system had ISDN-PRI D-channel links administered, check that those
links are in-service.