Upgrading a Multicarrier G2 Universal Module to Avaya
DEFINITY Server R EPN running Avaya Communication
Manager
555-233-115
5-38
Issue 7 November 2003
Check Customer Options
1. Type display system-parameters customer-options and press
Enter
to
set the customer options that were purchased.
Ensure that the
G3 version:
field is V11.
2. If the customer was using Supplementary Services Protocol b or d on an
ISDN-PRI trunk group before the upgrade, go to screen 7, QSIG Optional
Features, and ensure that the
Basic Call Setup
field is y.
Save Translations
1. Type save translation and press
Enter
to get upgraded translations onto
disk. If the translations were corrupted during the upgrade, the following
error message displays when logging in:
!
WARNING:
Translation corruption detected; call Avaya distributor immediately.
NOTE:
The save translation command cannot function if the translation
corruption message appears.
Back Up Disk
1. Type backup disk and press
Enter
to backup all changed files.
2. Type test stored-data long and press
Enter
. This instructs the system to
verify the consistency of the MSS files (on the disk and removable media).
Return Replaced Equipment
Return unused G2 equipment to Avaya.