Administer Fiber Links
Issue 7 November 2003
A-9
555-233-115
Form instructions
Page 1 of the form
Screen A-1.
Fiber Link Administration form
Basic Fiber Link Administration.
The following fields appear:
■
Fiber Link #
—
Display-only field. From the command line, enter a 1- to
3-digit number to uniquely identify a switch connection in the system and its
duplicate if appropriate.
■
Board Location
—
Enter the cabinet, carrier, and slot that identifies the
physical location of an SNI or EI board that is the first endpoint of the fiber
link.
■
Board Type
—
Display-only field showing the type of circuit pack in
Endpoint-1.
■
Board Location
—
Enter the cabinet, carrier, and slot that identifies the
physical location of an SNI or EI board that is the second endpoint of the
fiber link.
■
Board Type
—
Display-only field showing the type of circuit pack in
Endpoint-2.
■
Is one endpoint remoted via a DS1 Converter Complex?
—
Enter y to
specify that a DS1 Converter complex is used to remote one endpoint. If a
y is entered, A-PNC DS1 Converter circuit pack Location must be
administered on Page 1. A-PNC DS1 Converter circuit pack Type displays.
A-PNC DS1 Converter (DS1CONV) Attributes must be administered on
Page 2 of this form.
■
Fiber Translation
—
Enter multi-mode or single-mode. This field is used
for faster remote diagnosis.
■
Converter
—
Enter y or n. This field is used for faster remote diagnosis.
Page 1 of 1
FIBER LINK ADMINISTRATION
Fiber Link #: 1
Is one endpoint remoted via a DS1 Converter Complex? ___
ENDPOINT-1 ENDPOINT-2
(A-PNC) (A-PNC)
Board Location: _____
Board Location: _____
Board Type: xxx
Board Type: xxx
Fiber Translation:
Converter?
Type of Transceivers:
Converter Type: