Upgrading G3vs to an Avaya DEFINITY Server R
running Avaya Communication Manager
555-233-115
3-12
Issue 7 November 2003
Save Announcements
NOTE:
The TN750C and TN2501AP Integrated Announcement circuit packs store
announcements in nonvolatile memory; saving the announcements is
optional.
1. If the PPN contains a TN750B Announcement circuit pack, type display
announcements and press
Enter
.
2. If administered recorded announcements are listed, type save
announcements cabinet carrier slot and press
Enter
. For example,
01D03. This takes about 30 minutes.
NOTE:
For some software loads, type save announcements from cabinet
carrier slot. Type help and press
Enter
for complete command
usage.
3. Remove the translation card and install the backup translation card
Back Up Disk
1. Type backup disk and press
Enter
to write all information from the disk to
the backup tape. This takes 30 to 40 minutes.
Check ISDN Signaling Group States
1. Type list signaling-group and press
Enter
.
2. Type status signaling-group and press
Enter
to determine if ISDN is in
service. If it is not, follow normal maintenance procedures.
Shut Down DEFINITY LAN Gateway System
!
WARNING:
Neglecting to shut down the LAN Gateway assembly before powering down
the system cabinet where it resides can damage the LAN Gateway disk.
1. Log onto the DEFINITY LAN Gateway.
2. On the main menu, select Maintenance > Reset System > Shutdown.
3. Unseat the LAN Gateway assembly from its backplane connectors.