Adding New Carriers and EPN Cabinets
555-233-115
6-26
Issue 7 November 2003
Relocate Port Carrier B
Refer to
to relocate the removed port carrier.
Connect Management Terminal or PC
1. Behind control carrier “A,” disconnect the management terminal or PC
cable from the “TERM” connector, and reconnect the cable to the “DOT”
(duplication option terminal) connector.
Reseat DEFINITY LAN Gateway System
1. Reseat the LAN Gateway assembly into its backplane connectors.
Reseat DEFINITY AUDIX System
1. If a DEFINITY AUDIX System resides in the PPN or an EPN (where PPN
port carrier “B” was relocated), reseat the AUDIX assembly to its backplane
connectors.
Power Up System
1. At an EPN (where PPN port carrier “B” was relocated), set the main circuit
breaker to ON.
2. At the PPN, set the main circuit breaker to ON.
3. The system performs a level 4 rebooting process, loading the system
program and default or current translations from the disk. Rebooting takes
5 to 11 minutes.
NOTE:
Ignore alarms for now.
4. Type the reset system 4 and press
Enter
to copy the translations from
removable media to memory.
5. Clear any alarms.
6. Type save translation [both] and press
Enter
if translation changes were
made in Step 8.
7. Type restore disk [both] full and press
Enter
to copy the translations from
removable media to disk.
8. Verify that the EMERGENCY TRANSFER CONTROL switch is set to
AUTO. This restores the system to the normal operating mode.