Interconnect Port Networks with Fiber Optic Cabling
Issue 7 November 2003
4-49
555-233-115
For 1 or 2 Fiber-Remoted Expansion Port Networks
1. Behind port carrier C of the multicarrier PPN. See
:
a. Install a lightwave transceiver on the connector at slot 1C02.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
b. Connect a fiber optic cable to the transceiver just installed.
c. Route the fiber cable to the cabinet cable tray and out of the cabinet
through the cable manager to the PDS cross-connect facility.
d. Connect the fiber cable to the lightguide interface unit provided.
e. Carefully attach the fiber optic cable (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
2. Behind control cabinet A of EPN stack 2:
a. Install a lightwave transceiver on the connector at slot 2A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
b. Connect a fiber cable to the transceiver just installed.
c. Route the fiber cable down the outside of the rear covers and
through the cable manager to the PDS cross-connect facility.
d. Connect the fiber cable to the lightguide interface unit provided.
e. Carefully attach the fiber optic cable (with cable ties) to the rear
covers of the EPN stack.
f. Coil the surplus fiber optic cable and place it in the cable manager.