Add Multiple Integrated Announcement Circuit Packs
Issue 7 November 2003
7-37
555-233-115
LAN cable
The TN2501AP circuit pack does not include cables to connect the circuit pack to
your LAN. The following table lists the cable category and connection port.
Installing the TN2501AP Circuit Pack
Before you start
Ensure that you have the required hardware (see
Switch administration before hardware
installation
Before inserting the circuit pack into a carrier, an Avaya representative must
administer the VAL customer options. Before installing the hardware, check your
system for the following administration:
1. At the SAT, type display system-parameters customer-options and
press
RETURN
.
The System Parameters Customer Options screen appears.
2. Verify that the
G3 Version
field is set to V9 (or higher).
1. Verify that
Maximum VAL Boards
field is set to 1 or greater, up to the
maximum number allowed in the system.
NOTE:
Any value greater than the default (1) means that you have the
Enhanced offer.
2. Move to page 4.
3. Verify that the
VAL Full 1-Hour Capacity?
field is set for the offer that
you purchased:
■
n for Standard offer (10 minutes storage time) and only 1 circuit
pack.
■
y for Enhanced offer (1 hour storage time) and multiple circuit
packs.
Ethernet connection speed
Cable
Connection description
10 Mbps
Category 3
Connects through the RJ45 jack
(note #2 in
100 Mbps
Category 5